Mitsubishi FR-E520-0.1K-NA Instruction Manual page 80

Transistorized inverter, high performance & high function
Table of Contents

Advertisement

Param-
Func-
eter
tion
Number
Remote setting function
59
selection
Shortest acceleration/
60
deceleration mode
Reference I for intelligent
61
mode
Ref. I for intelligent mode
62
accel
Ref. I for intelligent mode
63
decel
65
Retry selection
Stall prevention operation
66
level reduction starting
frequency (Note 6)
Number of retries at alarm
67
occurrence
68
Retry waiting time
Retry count display
69
erasure
Special regenerative
70
brake duty
71
Applied motor (Note 6)
72
PWM frequency selection
73
0-5V/0-10V selection
74
Filter time constant
Reset selection/
75
disconnected PU detection/
PU stop selection
Parameter write disable
77
selection
Reverse rotation
78
prevention selection
Operation mode selection
79
(Note 6)
80
Motor capacity (Note 6)
82
Motor exciting current
Rated motor voltage
83
(Note 6)
Rated motor frequency
84
(Note 6)
90
Motor constant (R1)
Auto-tuning setting/status
96
(Note 6)
Setting
Name
Range
0, 1, 2
0, 1, 2,
11, 12
0 to 500A,
9999
0 to 200%,
9999
0 to 200%,
9999
0, 1, 2, 3
0 to 400Hz
0 to 10,
101 to 110
0.1 to 360 s
0
0 to 30%
0, 1, 3, 5, 6,
13, 15, 16, 23,
100, 101, 103,
105, 106, 113,
115, 116, 123
0 to 15
0, 1
0 to 8
0 to 3,14 to
17
0, 1, 2
0, 1, 2
0 to 4,6 to 8
0.1 to
7.5kW,
9999
(Note 8)
0 to 500A,
9999
0 to 1000V
50 to 120Hz
0 to 50Ω,
9999
0, 1
65
PARAMETERS
Minimum
Factory
Setting
Setting
Increments
1
0
1
0
0.01A
9999
1%
9999
1%
9999
1
0
0.01Hz
60Hz
(Note 3)
1
0
0.1 s
1 s
1
0
0.1%
0%
1
0
1
1
1
0
1
1
1
14
1
0
1
0
1
0
0.01kW
9999
0.01A
9999
200V/
0.1V
400V
0.01Hz
60Hz
(Note 3)
0.001Ω
9999
1
0
Custo-
Refer
mer
To:
Setting
97
99
99
99
99
101
83
101
101
101
86
103
104
105
106
106
108
109
110
113
115
115
115
115
115

Advertisement