Stall Prevention Function And Current Limit Function (Pr. 156) - Mitsubishi FR-E520-0.1K-NA Instruction Manual

Transistorized inverter, high performance & high function
Table of Contents

Advertisement

The zero current detection level setting should not be too high, and the
zero current detection time setting should not be too long. Otherwise, the
detection signal may not be output when torque is not generated at a low
output current.
To prevent the machine and equipment from resulting in hazardous
conditions by use of the zero current detection signal, install a safety
backup such as an emergency brake.

4.2.40 Stall prevention function and current limit function (Pr. 156)

Pr. 156 " stall prevention operation
selection"
You can make settings to disable stall prevention caused by overcurrent and to disable
the inverter from an overcurrent trip if an excessive current occurs due to sudden load
variation or turning the inverter's output side ON-OFF (to disable the fast-response
current limit which limits the current).
Parameter
Factory
Number
Setting
156
CAUTION
Setting
Range
0
0 to 31, 100
144
PARAMETERS
Related parameters
Pr. 22 "stall prevention operation level"
Pr. 23 "stall prevention operation level
compensation factor at double
speed"
4