Volvo Penta TAMD74A-A Operator's Manual page 68

Engines with electrical system cu2500f
Table of Contents

Advertisement

Technical Data
Fuel system
Injection pump, setting:
TAMD74A-A ........................................................
TAMD74A-B ........................................................
Fuel specification
The fuel must comply with national and international standards for commercially supplied fuels,
such as:
EN 590 (with national environment and cold requirements)
ASTM D 975 No 1-D and 2-D
JIS KK 2204
Sulfur content: Complying with legal requirements in each country.
Low density fuel (urban diesel in Sweden and city diesel in Finland) can cause a loss of up to 5% of power and an
increase in fuel consumption of about 2–3%.
Cooling system
Freshwater system capacity including heat
exchanger, approx. .............................................
Electrical system
System voltage ...................................................
AC generator,
voltage/max. amperage ...................................
output, approx. ................................................
Alternative generator equipment (accessory):
voltage/max. amperage ...................................
output, approx. ................................................
Battery capacity ..................................................
Battery electrolyte density at +25°C (77°F):
fully charged battery ........................................
battery recharged at ........................................
* Note. Applies to batteries with tropical acid.
66
15° ±0.5° BTDC.
12° ±0.5° BTDC.
34 liters (9.0 US gals)
24 V
28 V/60 A
1700 W
28 V/100 A
2800 W
2 connected in series 12V, max. 143 Ah
3
1.28 g/cm
= 0.0462 lb/in
3
1.24 g/cm
= 0.0448 lb/in
3
3
(1.24 g/cm
= 0.0448 lb/in
3
3
(1.20 g/cm
= 0.0434 lb/in
3
)*
3
)*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tamd74a-b