The appearance of the LCD screen on the control unit
varies, depending on what functions and settings are
choosen. There are four different screen views avail-
able. These are:
– Instrument view
– Alarm list
– Information view
– Event Log
The instrument view is the main view of the control
unit.
Pushing the CHANGE VIEW button will change the
screen view from the instrument view to the alarm list.
The information view is displayed by pushing the
CHANGE VIEW button for one second. To get back
to the previous view, the CHANGE VIEW button is
pushed again. The log is shown when the LOG button
is pushed (please refer to chapter "Troubleshooting").
Instrument view
The instrument view is the main view of the control
unit. The instrument view shows an upright standing
tachometer (2), as well as a varying number of
horisontal gauges (6) showing the positions of the an-
alogue senders on the engine. Which horisontal
gauges are displayed depends on the settings made
when installing the engine.
The status text fields located at the bottom of the in-
strument view (3, 4 and 5) shows current running
mode. Located at the top of the instrument view is a
normally empty field (1), in which the first alarm to
start will be described with a text string. The text in
the field blinks with inverted text until the alarm is ac-
knowledged.
At the upper left corner of the screen * and + is alter-
nately seen when an alarm is active. The */+ blinking
will end when the ACKNOWLEDGE button is pushed
to acknowledge the alarm. The inverted text disap-
pears when the alarm stops.
Control panel
15