Blast Tube Length; Securing The Burner To The Boiler; Nozzle Installation - Riello RLS 38/E Installation, Use And Maintenance Instructions

Dual fuel light oil/gas burners
Table of Contents

Advertisement

4.5

Blast tube length

The length of the blast tube must be selected according to the indi-
cations provided by the manufacturer of the boiler, and it must be
greater than the thickness of the boiler door complete with its insu-
lation.
The range of lengths available, L (inch), is as follows:
Model
(short blast tube)
RLS 38/E
RLS 50/E
1
14
4.6

Securing the burner to the boiler

Detach the combustion head from the burner (Fig. 11):
➤ remove screw 14) and withdraw the cover 15);
➤ disconnect the oil pipes by unscrewing the two connectors 4);
➤ remove the screws 2) from the slide bars 3);
➤ remove screw 1) and pull the burner back on slide bars 3) by
about 4".
4.7

Nozzle installation

The burner complies with the emission requirements of the UL 296
Standard.
In order to guarantee that emissions do not vary, recommended
and/or alternative nozzles specified by the manufacturer in the In-
struction and warning booklet should be used.
It is advisable to replace nozzles every year during
regular maintenance operations.
WARNING
L
L
(long blast tube)
29
7
7
/
"
13
/
32
32
1
13
8
/
"
13
/
2
16
15
2
D10465
Installation
For boilers with front flue passes 13)(Fig. 11) or flame inversion
chambers, protective insulation 11) must be inserted between the
boiler refractory 12) and the blast tube 10).
This protective insulation must not compromise the extraction of
the blast tube.
For boilers having a water-cooled front the insulation 11)-12) is not
required unless it is required by the boiler manufacturer.
"
"
7
4
3
4"
➤ Disconnect the electrode wires and then pull the burner com-
pletely off the slide bars.
➤ Secure the flange 9) to the boiler plate, inserting the gasket 6).
➤ Use the 4 screws, also supplied with the unit, after first pro-
tecting the thread with an anti-locking product.
➤ The seal between burner and boiler must be airtight.
The use of nozzles other than those specified by the
manufacturer and inadequate regular maintenance
may result into emission limits non-conforming to
the values set forth by the regulations in force, and
in extremely serious cases, into potential hazards to
people and objects.
CAUTION
The manufacturing company shall not be liable for
any such damage arising from nonobservance of
the requirements contained in this manual.
19
GB
13
8
9
10
L
5
13
6
12
11
Fig. 11