• The chimney flue must be provided CE in accordance with EN 1443 regulation. Please find attached an example of label:
3.5

CHIMNEY POT

The chimneypot, meaning the end part of the flue, must meet the following characteristics:
• the smoke outlet section must be at least double the internal section of the chimney;
• prevent the penetration of rain or snow;
• ensure the outlet of smoke even in the event of wind (windproof chimneypot);
• the height of outflow must be beyond the reflux area (**) (refer to national regulations to identify the reflux area);
• always be built at a distance from antennas or dishes, and never be used as a support.
(**) unless there are specific national derogations (clearly specified in the corresponding instruction manual in English) which under
appropriate conditions allow it; in this case, strictly follow the product/installation requirements of the relative regulations/technical
specifications/legislation in force in that country.
6
Fig. 3 - Chimney Flues
LEGEND
Fig. 3
1
Chimney flue with insulated stainless-steel pipes
2
Chimney flue on the existing chimney
3
Inspection plug
4
Inspection door
Fig. 4 - Example of label