6.14 Ducting Data; 6.15 Electric Connection - Cadel AMARANTO 9 Installer Manual

Hide thumbs Also See for AMARANTO 9:
Table of Contents

Advertisement

6.14 DUCTING DATA

• If the stove is not fitted with ducting system, it provide a hot air capacity ranging from a minimum of 44 m
of 86 m
/h with a temperature ranging between 95°C and 122°C.
3
• For the ducting system, we recommend using a pipe with a maximum length of 7 mt and up to three 90° elbows in order to
maintain hot air temperature.
• Use pipes with smooth internal surface and a diameter of 80 mm.
• Fit the pipe with insulating material if it passes through a cold wall.
• The outlet must be protected by a grid with wide mesh and a minimum total surface area of 40 cm
• If the pipes used are longer than 7 mt, the air capacity ranges from a minimum of 34 m
temperature from 50°C to 70°C. (These values refer to the laboratory used for the tests. The room where the stove is installed
may register different values both in terms of capacity and temperature).
• If you wish to increase air capacity, install at the end of the pipe a small wall-mounted fan with a capacity exceeding 130 m
The installation must be carried out by an authorised technician.
• According to the factory parameters, 1/2 of the generated heat is conveyed into the room where the stove is installed, while
the remaining 1/2 are conveyed through the left ducting pipe system.
• See the dedicated chapter of the USER MANUAL for the various adjustments.

6.15 ELECTRIC CONNECTION

Warning: the appliance must be installed by an authorized technician!
• The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension
specific of every model, as described in the technical datas table (see FEATURES a pag. 32).
• The plug must be easily accessible when the appliance is installed.
• Please further assure you that your network is endowed with an efficient earth connection: if it does not exist or if it is not
efficient, please endow you with one in compliance with the law.
• Connect the supply cable first on the back of the stove (see Fig. 67 and Fig. 68) and then at a wall electric socket.
24
Fig. 66 - Ducting system example
CRISTAL 9 - CRISTAL PLUS 9 - ICON PLUS 9 - AMARANTO 9 - LIFE 9 - STEEL 9 - ELANE 9
/h to a maximum
3
.
2
/h to a maximum of 60 m
/h and the
3
3
/h.
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Life 9Cristal 9Elane 9Cristal plus 9Icon plus 9Steel 9

Table of Contents