• Remove the inspection lid of the T-union (see Fig. 71).
• Extract the ash which has accumulated in the inner.
• After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary
replace it.
It is important to sealed the cap othrwise noxiuous fumes will propagate among the room.
7.3
FUME PASSAGES CLEANING
Clean the fume passages every year.
Fig. 72 - Remove the screws
• Open the door.
• Remove the 4 screws (see Fig. 72) and remove the inspection cap (see Fig. 73).
Fig. 74 - Clean with pipe cleaner
• Clean with a pipe cleaner and suction any ash accumulated inside (see Fig. 74 and Fig. 75).
• After cleaning, repeat the operation in reverse making sure the gasket is intact and efficient: if necessary, provide for the
replacement with original spare parts.
CRISTAL 9 - CRISTAL PLUS 9 - ICON PLUS 9 - AMARANTO 9 - LIFE 9 - STEEL 9 - ELANE 9
Fig. 71 - Fume conduit cleaning
Fig. 73 - Remove the inspection cap
Fig. 75 - Vacuum out the ash
27