Importing and exporting data
Using the import and export button, you can import or export the data of the I/O
communication table for the online assignment:
● When you export, the currently displayed data of the table is exported to a CSV file. Using
the filter function of the table, you can select which data will be exported.
● When you import, the data of the CSV file is written to the table. If there are conflicts with
values already existing in the table, you can decide whether the data should be
overwritten or whether the import needs to be stopped.
3.2.5

Permitting changes to the device name and IP address directly on the device

Introduction
Machines are frequently commissioned on site or integrated into the existing infrastructure
without STEP 7. You can find typical applications in all areas of the series machine building.
Alternative means for assigning the IP address are available for this.
Procedure
1. In the network or device view of the STEP 7 Hardware and Network editor, select the
PROFINET interface of an IO controller.
2. Navigate in the Inspector window to "Ethernet addresses".
3. Select the "IP address is set directly at the device" option in the "IP protocol" area.