Technical Specifica ons
5. Technical
Type
Specifica -
Ar cle number
ons*
Forward path (downstream)
Frequency Range (VHF BI on / RC on)
Max. Output level**, Slope 0/7 dB
Gain
A enua on
A enua on, Input
Slope, Interstage, Jumper
Slope, Input
Noise Figure
Return path (upstream)
Frequency Range (VHF BI on / RC on)
Max. Output level (IMA2 / IMA3) > 60dB
Upstream load (KDG 1TS 140)
Gain (-6dB*** / max)
A enua on, Interstage, Jumper
A enua on, Input
Slope, Interstage, Jumper
Noise Figure
General
Linearity
Return loss (@40MHz, -1.5dB/Oktave)
Test connector (75Ω) Input/output/test
Test connector In-/Output (-20dB)
Opera ng condi ons
Diameters W x H x D
Input supply voltage
Power Consump on (typ.)
ESD/Surge protec on
Opera ng temperature
Safety/Protec on
Weight
*) Measured according to EN 60728-3 **) CTB and CSO > 60 dB (42 ch.) ***) Switching gain in first amplifier by using one jumper
Repair only by an Authorized Technician and Service Center.
6. Mainte-
Please refer to Your Sales Representa ve for more info.
nance /
Service
You must adhere to the Legal Requirements and precau ons that applies to your
local Area for Recycling this product.
Art. No.: 892288—G.2019.05.09
Interstage
Jumper
,
,
16
GHV 920
GHV 930
323150
323158
MHz
47...1006 / 85...1006
dBµV
98/100
103/105
dB
20
30
dB
dB
0...15 (1dB-Steps)
dB
0 / 3 / 7 / 10
dB
0...15 (1dB-Steps)
dB
MHz
dBµV
96/117
Typ C
Typ C
dB
20 fixed
22/28
dB
dB
0...15 (1dB-Steps)
dB
0 / 3 / 6 / 9
dB
dB
dB
Bi- / Uni-direc onal
mm
169 x 76 x 65
190—264 / 50...60
V~/Hz
W
4,9
6,0
kV
°C
Class II / IP 20
g
GHV 935
GHV 940
323162
323166
103/105
107/109
35
40
0 / 6
7
- / 5...65
98/119
Typ C
Typ D
24/30
26/32
0 / 6
5
± 1
>18
F-female
6,4
9,5
10 / 1
-25...+55
750
GHV 900 Serie