Triax TMB 200S Manual

Triax TMB 200S Manual

Programmable multiband amplifier

Advertisement

Quick Links

Programmable Multiband Amplifier
TMB 200 & TMB 200S
Programmable Multiband Amplifier
&
TMB 200
TMB 200S
Manual
July 2014 – V1.0
0
awi -july 14
TMB 200-V1

Advertisement

Table of Contents
loading

Summary of Contents for Triax TMB 200S

  • Page 1 Programmable Multiband Amplifier TMB 200 & TMB 200S Programmable Multiband Amplifier & TMB 200 TMB 200S Manual July 2014 – V1.0 awi -july 14 TMB 200-V1...
  • Page 2: Table Of Contents

    Programmable Multiband Amplifier TMB 200 & TMB 200S General information ..........................2 Safety instructions ............................ 2 Installing the unit ............................3 Programming the unit ..........................4 Configuring the unit ..........................5 Operating principle ..........................5 Flow chart System menus......................... 6 Flow chart Configuration menus ......................
  • Page 3: General Information

    Programmable Multiband Amplifier TMB 200 & TMB 200S The processing units in the TMB200 range are used to selectively filter digital and analogue UHF channels. These units also couple and amplify VHF programmes according to the satellite band model (IF).
  • Page 4: Installing The Unit

    Programmable Multiband Amplifier TMB 200 & TMB 200S We recommend you install the unit in a sufficiently ventilated place. Natural ventilation must be able to occur through the ventilation grids; leave a minimum space of 15 cm around the unit to ensure maximum ventilation.
  • Page 5: Programming The Unit

    Programmable Multiband Amplifier TMB 200 & TMB 200S An external keypad and display is used to setup the unit. A USB cable is used to connect the unit and the keypad. Running through the menus ( - Select the value "-"...
  • Page 6: Configuring The Unit

    Programmable Multiband Amplifier TMB 200 & TMB 200S Connect the Keypad and the unit with the USB chord. USB A on TMB: USB mini B on keypad: Operating principle To access the configuration menus, press a button. In standby mode the display shows the date and time.
  • Page 7: Flow Chart System Menus

    Amplificateurs programmables TMB 200 & TMB 200S awi -juin 14 TMB 200-V1...
  • Page 8: Flow Chart Configuration Menus

    Programmable Multiband Amplifier TMB 200 & TMB 200S TMB 001 Display 2s V xxx.xx Boot load Tree loading TMB 200 (S) Automatic connection to the device when keyboard is connected or when you action a button on the keyboard Setup...
  • Page 9: Menus

    Programmable Multiband Amplifier TMB 200 & TMB 200S Connect your USB cable between the unit and the keypad. After boot process the display shows TMB200/Setup and the LED in on. Press a button to access the menus. Keypad in standby mode (the display shows time and date), press a button to access the menus.
  • Page 10: Factory Reset

    Programmable Multiband Amplifier TMB 200 & TMB 200S Factory reset. Firmware Settings Menu 14a23 / Config Firmware Firmware Firmware Firmware Firmware Menu Menu wait upload DTMB_00x [ == > ] Complete Factory Factory Menu Reset wait  scroll through the menus with button  or  until display shows Factory Reset ...
  • Page 11: Lte Function

    Programmable Multiband Amplifier TMB 200 & TMB 200S LTE function Firmware Settings Menu 14a23 / Config Firmware upload Factory Reset Import Config Export Config Menu Menu 21-60 21-69 21-60  scroll through the menus with button  or  until display shows LTE ...
  • Page 12: Configuration Menus

    Programmable Multiband Amplifier TMB 200 & TMB 200S Configuration menus This allows to:  Configuration of filter distribution on UHF1, 2 and 3 inputs. Comb 0010  Selection of remote power supply (12 or 24 VDC). 12 or 24 VDC ...
  • Page 13: Selection Of Remote Power Supply Voltage

    Programmable Multiband Amplifier TMB 200 & TMB 200S Selection of remote power supply voltage. Settings / Config IN UHF IN UHF Menu COMB 1000 COMB 0010 Voltage Voltage Voltage Menu Menu DC UHF DC UHF Menu UHF1 off  Keypad in standby mode, press a button to access to SETTINGS/Config.
  • Page 14: Uhf Gain

    Programmable Multiband Amplifier TMB 200 & TMB 200S UHF gain DC UHF DC UHF Menu UHF1 off UHF Gain UHF Gain UHF Gain Menu Menu AMP IN AMP IN Menu UHF1 OFF  Unit in standby mode, push a button to reach the SETTINGS/Config menu.
  • Page 15: Uhf Filters Setup

    Programmable Multiband Amplifier TMB 200 & TMB 200S UHF filters setup. AMP IN UHF CHAN UHF CHAN UHF CHAN Menu Menu Menu F1 21-25 F1 21-25 F1 21 - __ UHF CHAN Menu Tun -9 +9 CHAN UHF UHF CHAN...
  • Page 16: Uhf Filter Level Setting

    Programmable Multiband Amplifier TMB 200 & TMB 200S UHF filter level setting. F1 21-25 F1 21-25 Menu Menu Att 00 F1 21-25 Menu Fx 61 Fx 61 Menu Menu Att 00 Fx 61 Menu UHF Att UHF Att Menu Menu...
  • Page 17: Agc

    Programmable Multiband Amplifier TMB 200 & TMB 200S Menu Menu Error code Auto Auto Level AUTO lvl Menu Menu Wait  Unit in standby mode, push a button to reach the SETTINGS/Config menu.  Press the  button until the display shows the AGC menu.
  • Page 18: Sat Menu

    TMB 200 & TMB 200S SAT Menu TMB 200S models have one IF amplification channel. The Sat menu is used to configure the remote power supply of the LNB (OFF / 13 /17 V ), to activate the 22kHz generator and the 9dB equalizer.
  • Page 19: Tmb 200S Diagram

    Programmable Multiband Amplifier TMB 200 & TMB 200S BI/FM UHF1 UHF2 UHF3 0/12/24V 0/12/24V 0/12/24V 0/13/17V 0/22kHz 0-20dB 0-20dB 0-20dB 0-20dB 0/9dB 0-20dB awi -july 14 TMB 200-V1...
  • Page 20: Technical Specifications

    Programmable Multiband Amplifier TMB 200 & TMB 200S TMB 200 TMB 200S Type Unités Part nr. 360221 324222 Nombre d'entrées AMPLIFICATION 90 / 80 /75- 95/ - 90 / 80 /75- 95/ 80 Max. BI_FM / BIII / UHF / SAT input level...