This appliance can be installed in ducted or recirculation
mode.
Ducted mode (Fig. 4)
In ducted mode, the extractor hood fan extracts the
cooking vapours and passes them through the
grease filter. The air then flows to the outside.
The grease filter absorbs the solid particles in the
cooking vapors.
In this mode, only grease filters are installed
(charcoal filter is optional).
Fig. 4
Recirculation mode (Fig. 5)
In recirculation mode, the extractor hood fan
extracts the cooking vapors which are purified in the
grease filter and charcoal filter.
The purified air is then recirculated into the kitchen
via a vent opening in the hood. The grease filter
absorbs the solid particles in the cooking vapors.
The charcoal filter is designed to absorb cooking
odor. In this mode, both grease filters and charcoal
filters are installed.
Fig. 5
Connection to exhaust air pipe (Fig. 6 & 6.1)
Attach Ø150mm pipe directly to the air outlet and
secure appropriately (Fig. 6).
If using Ø120mm pipe, connect to the air outlet
using a reducing connector (not provided).
Secure both joints appropriately (Fig. 6.1).
Connect pipe to the outdoor duct.
Fig. 6
Fig. 6.1

INSTALLATION

Wall mounting (Fig. 7 & 8)
Do ensure that the appliance is mounted on a solid
surface which could withstand the appliance's weight.
Draw a vertical line at the center of the wall.
From bench top (see A), draw a horizontal line above
minimum installation height level (see B).
Mark a reference point at C. Repeat this step on the
other side.
Drill Ø 8mm holes at center of marking points. Insert
wall plugs in the wall.
Fix the hood body to wall using 2 (two) ST5 x 50
screws provided. Tighten screws firmly. Note: Adjust
the hood body alignment if necessary (Fig. 9).
Place mounting bracket on the wall at desired height
level. Align bracket center at vertical line (see D).
Mark the center of the bracket holes and drill Ø 8mm
holes. Insert wall plugs in the wall.
Secure mounting bracket firmly using 2 (two) ST5 x
25 screws provided.
Fix the inner duct to mounting bracket using 2 (two)
M4 x 8 screws provided (Fig. 8).
Slide the outer duct downwards and ensure that it is
well seated on the hood body.