148 Technical data

Ambient conditions

Environmental limits for the drive are given below. The drive is to be used in a heated,
indoor, controlled environment.
Installation site altitude
Air temperature
Relative humidity
Contamination
Pollution degree
IEC/EN 60664-1
Vibration
IEC/EN 61800-5-1
IEC 60068-2-6:2007,
EN 60068-2-6:2008
Shock
IEC 60068-2-27:2008, EN
60068-2-27:2009
Operation
installed for stationary
use
0...2000 m (0...6562 ft)
above sea level. For alti-
tudes over 2000 m, con-
tact ABB.
Output derated above
1000 m (3281 ft).
0 ... +45 °C
(+32 ... +113 °F), no con-
densation allowed. Out-
put derated in the range
+45 ... +55 °C
(+113 ... +131 °F).
For UL and CSA compli-
ant installations, the
maximum surrounding
air temperature is 40 °C
(104 °F).
Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the
IEC/EN 60721-3-3:2002
Chemical gases: Class
3C2
Solid particles: Class 3S2.
No conductive dust al-
lowed.
IEC/EN 60721-3-3:2002
10...57 Hz: max.
0.075 mm amplitude
57...150 Hz: 1 g
Units with marine con-
struction (option +C121):
Max. 1 mm (0.04 in)
(5 ... 13.2 Hz), max. 0.7 g
(13.2 ... 100 Hz) sinusoid-
al
Not allowed
Storage
in the protective pack-
age
-
-40 ... +70 °C
(-40 ... +158 °F)
Max. 95%
presence of corrosive gases.
IEC 60721-3-1:1997
Chemical gases: Class
1C2
Solid particles: Class 1S3
(packing must support
this, otherwise 1S2)
2
IEC/EN 60721-3-1:1997
10...57 Hz: max.
0.075 mm amplitude
57...150 Hz: 1 g
With packing max.
2
2
100 m/s
(328 ft/s
11 ms
Transportation
in the protective pack-
age
-
-40 ... +70 °C
(-40 ... +158 °F)
Max. 95%
IEC 60721-3-2:1997
Chemical gases: Class
2C2
Solid particles: Class 2S2
IEC/EN 60721-3-2:1997
2...9 Hz: max. 3.5 mm
amplitude
9...200 Hz: 10 m/s
2
(32.8 ft/s
)
With packing max.
2
)
100 m/s
(328 ft/s
11 ms
2
2
)

Advertisement