Regency City CV50E DIRECT VENT Owners & Installation Manual page 79

Table of Contents

Advertisement

CITY SERIES 50
12. Loosen 8 screws in locations shown below (4 at front and 4 at rear)—
slide burner to the left away from the orifice and lift out.
t t o o o o l l t t i i p p
t t o o o o l l t t i i p p
13. Remove burner orifice with a 3/8" wrench. Use another wrench to
hold on to the elbow behind the orifice. Discard orifice. Reinstall new
burner orifice LPG stamped #52 and tighten.
t t o o o o l l t t i i p p
14. Remove pilot retainer clip with pliers and pull off the pilot cap to
expose the pilot orifice.
Pilot retainer clip
920-708
Single-sided model shown
Burner screw locations
Single-sided model shown
Slide burner to the left and lift out
Single-sided model shown
Burner Orifice Location
15. Unscrew the pilot orifice with the Allen key; then replace with the LPG
pilot orifice and the pilot cap, provided in the kit.
16. Reinstall pilot cap and pilot retainer clip.
17. Prior to installing burner—adjust aerations settings - to 3/8" for LP.
Reinstall burner (see Step 11).
18. Make sure aeration cap tab is inserted into the slot on the bracket.
Adjust aeration handle if necessary.
Aeration cap tab
19. Reverse steps 1 to 11.
20. Ensure the pilot lilght is in the correct orientation to the burner.
Reconnect the gas and electrical supplies. Start the appliance (see
section on Lighting Instructions). Ensure that pilot and burner ignition
are completed without delay. Check inlet and outlet pressures at full
load. With a soapy solution, leak test the entire system. Verify correct
flame and pilot appearance.
21. See Gas Pipe Pressure Testing in manual.
Min. Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size
Maximum Input
Minimum Input
Altitude
Installer Notice:
These instructions must be left
with the appliance
2
installation
Slot on bracket
aeration
handle
City Series
LP SYSTEM DATA
11" WC (2.73kpa)
10.5" WC (2.62 kpa)
2.9" WC (0.72 kpa)
#52 DMS
33,000 Btu/h (9.67 kW)
17,000 Btu/h (4.98 kW)
0-4500 ft (0-1372m)
.
City Series CV50E |
07.27.23