Chapter 6 Fault Code Information; Common Problems And Solutions - Delta Electronics VFD S 115V Series User Manual

Compact low-cost easy-to-use general-purpose ac motor drives
Table of Contents

Advertisement

The AC motor drive has a comprehensive fault diagnostic system that includes several different
alarms and fault messages. Once a fault is detected, the corresponding protective functions will be
activated. The following faults are displayed as shown on the AC motor drive digital keypad display.
The three most recent faults can be read from the digital keypad or communication.
NOTE
Wait 5 seconds after a fault has been cleared before performing reset via keypad of input terminal.

6.1 Common Problems and Solutions

Fault
Fault Descriptions
Name
Over current
Abnormal increase in current.
Over voltage
The DC bus voltage has
exceeded its maximum
allowable value.
Revision August 2008, SE09, SW V2.61

Chapter 6 Fault Code Information

1.
Check if motor power corresponds with the
AC motor drive output power.
2.
Check the wiring connections to U/T1, V/T2,
W/T3 for possible short circuits.
3.
Check the wiring connections between the AC
motor drive and motor for possible short
circuits, also to ground.
4.
Check for loose contacts between AC motor
drive and motor.
5.
Increase the Acceleration Time.
6.
Check for possible excessive loading
conditions at the motor.
7.
If there are still any abnormal conditions when
operating the AC motor drive after a short-
circuit is removed and the other points above
are checked, it should be sent back to
manufacturer.
1.
Check if the input voltage falls within the
rated AC motor drive input voltage range.
2.
Check for possible voltage transients.
3.
DC-bus over-voltage may also be caused by
motor regeneration. Either increase the
Decel. Time or add an optional brake resistor.
4.
Check whether the required brake power is
within the specified limits.
Corrective Actions
6-1

Advertisement

Table of Contents
loading

Table of Contents