Axis Specifications Parameters - Mitsubishi Electric MELDAS C6 Parameter Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

6. Axis Specifications Parameters

6.1 Axis Specifications Parameters
After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the
parameter, turn on the power again.
#
Items
2001 rapid
Rapid
traverse
feedrate
2002 clamp
Cutting
feedrate for
clamp
function
2003
smgst
Acceleration
(PR)
and deceler-
ation modes
6. Axis Specifications Parameters
6.1 Axis Specifications Parameters
Details
Set up the rapid traverse feedrate for each axis. The
maximum value to be set differs with mechanical
systems.
Define the maximum cutting feedrate for each axis.
Even if the feedrate in G01 exceeds this value‚ the
clamp will be applied at this feedrate.
Specify acceleration and deceleration control modes.
F
E
D
C
B
A
9
8
OT3 OT2 OT1 C3
(Note) Set 0 in null bits.
Rapid traverse feed acceleration and deceleration
types
LR: Linear acceleration/deceleration
R1: Primary delay
R3: Exponential acceleration and linear
deceleration
(Note) Designate "F" with bits 0 to 3 for rapid traverse
with acceleration/deceleration by software.
Note that the acceleration/deceleration by
software will not applied on such case as
follows;
(1) When the parameters are set as "#1205
G0bdcc" = "1" (acc/dec before G00 is
valid) and "#1086 G0Intp" = "0" (G00
non-interpolation invalid), the
acceleration/deceleration before
interpolation will be applied to the
following operation.
(a) Travel by G00 command
(b) Travel from G28/G30 command start
point to the intermediate point
(c) Travel from G29 command reference
to the intermediate point
(Continued on the next page)
66
Get other manuals https://www.bkmanuals.com
7
6
5
4
3
2
1
0
C1 LC R3
R1 LR
Setting range
(unit)
1 to 1000000
(mm/min)
1 to 1000000
(mm/min)
Specify the modes