Indexing Axis Commands - Mitsubishi Electric MELDAS C6 Parameter Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

15. Indexing Axis Commands

(Note) These parameters are used only with the G64T.
Item
POSITION
SPEED
INPOS
FLAG
100 sets can be set for each axis.
When changing the axis, set the axis No. after "X" in the first setting area, such as # (X2), and then
press INPUT. Axis No. "1" corresponds to the 1st peripheral axis.
(Example 1) To change to 2nd peripheral axis
(Example 2) To change to 4th peripheral axis
15. Indexing Axis Commands
Details
Command the indexing position.
Set the indexing speed.
Set the in-position width, which indicates the output
range of the in-position signal output when
positioning is completed.
0: Normal indexing position command
1: Position command valid for external positioning
2: Indexing command compensation valid
290
Get other manuals https://www.bkmanuals.com
Setting range (unit)
–99999.999
to 99999.999
0 to 999999
(mm/min, °/min)
0 to 99999.999
0/1/2
# ( X2) INPUT
# ( X4) INPUT
(0.001mm/0.001°,
0.0001mm/0.0001°)
(0.001mm/0.001°,
0.0001mm/0.0001°)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents