Setting "Slave" mode

Put all the modules in "Slave" mode: switch 3 on OFF and switch 4 on ON.
Figure 15: Slave mode
Caution:
All the switch configurations of the modules of one column must be the
same as the modules opposite on the other column that constitutes the barrier.

Module numbering

Determine positions of the modules inside a column.
Note:
The numbers designating the positions must follow from bottom to top. If
there are less than 4 modules inside a column, there should not be gaps or
overlaps in the numbering (see Table 8 below).
Table 8: Allowed module numbering
Position 1
2 modules
X
3 modules
X
4 modules
X
20
Position 2
Position 3
X
X
X
X
X
SB Series AIR Beam Detectors Installation Manual