Fuser Unit Temperature Control - Samsung MultiXpress K7 Series Service Manual

A3 mono copier
Table of Contents

Advertisement

2.6.3. Fuser unit temperature control

When the main switch turns on, the CPU turns on the fusing lamp. The lamp stays on until the NC sensors detect the standby
temperature. Then the CPU raises the temperature up to the printing temperature.
■ Overheat Protection
The CPU cuts power to the fusing lamp in the following cases :
The belt temperature detected by the NC sensors keeps higher than 220°C for 20 sec.
The belt temperature detected by the NC sensors keeps higher than 230°C for 3 sec.
The relay off works when belt temperature detected by the NC sensors is higher than 230°C
The following components are used when thermistor overheat protection fails :
Two thermostats get into line with the common ground wire of the fusing lamp.
If one of the thermostat temperatures becomes higher than 195°C, it opens and cuts power to the fusing lamp. If the
other thermostat temperature becomes higher than 195°C, it also opens and cuts power to the fusing lamp.
Copyright© 1995-2017 SAMSUNG. All rights reserved.
2. Product Specifications and Description
2-49

Advertisement

Table of Contents
loading

Table of Contents