CHAPTER 1 PRODUCT HANDLING AND SPECIFICATIONS
1.8
Program Execution Output Terminal Specifications
The emulator has an EMUL terminal that outputs program execution signals.
I Program execution output terminal specifications
A program execution signal is output continuously while a user program is being executed.
Table 1.8-1 "Program execution output terminal specifications" lists the program execution
output terminal specifications, and Figure 1.8-1 "Configuration of the peripheral circuit for the
program execution output terminal" shows the corresponding peripheral circuit configuration.
Table 1.8-1 Program execution output terminal specifications
Terminal name
EMUL
Figure 1.8-1 Configuration of the peripheral circuit for the program execution output terminal
From internal emulator circuit
10
Input or output
Output
Outputs user program execution signals.
An Level-H signal is output continuously while a user
program is being executed.
74LVC244
(V
=3.3V)
cc
GND
Get other manuals https://www.bkmanuals.com
Description
33 Ω
EMUL terminal
BNC connector
GND