Technical specifications
Article number
Interface types
M12 port
•
•
•
Protocols
Supports protocol for PROFINET IO
PROFINET CBA
PROFIsafe
EtherNet/IP
Modbus TCP
PROFINET IO Device
Services
Redundancy mode
•
•
•
Media redundancy
EtherNet/IP
Services
Updating times
Redundancy mode
Address area
78
Autonegotiation
Autocrossing
Transmission rate, max.
–
IRT
–
Prioritized startup
–
Shared device
–
Number of IO Controllers with shared de-
vice, max.
PROFINET system redundancy (S2)
–
on S7-1500R/H
–
on S7-400H
PROFINET system redundancy (R1)
H-Sync forwarding
–
MRP
–
CIP Implicit Messaging
–
CIP Explicit Messaging
–
CIP Safety
–
Shared device
–
Number of scanners with shared device,
max.
–
Requested Packet Interval (RPI)
–
DLR (Device Level Ring)
–
Address space per module, max.
CM 8x IO-Link + DIQ 8x24VDC M12-L 8xM12 (6ES7148-6JJ00-0BB0) communications module
6ES7148-6JJ00-0BB0
Yes
Yes
100 Mbit/s
Yes
No
No
Yes
Yes
Yes; 250 µs to 4 ms in 125 µs frame
Yes
Yes
2
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes; 2x EtherNet/IP Scanner
2
2 ms
No
300 byte
Equipment Manual, 12/2022, A5E51718265-AB