8.4.2 Phones

Dual Phones
OFF, ON. Default: OFF. With Dual Phones ON the phones
output PH 1/2 will be active. Default state is Off, as PH 3/4
is the main phones output and should be used exclusively
unless two phones are to be connected.
If Dual Phones is on and two phones are plugged in, a push
on VOLUME toggles between 1/2, 3/4 and linked volume
control (with the marker over both). When VOLUME is
turned the Dual Volume screen is shown then.
Bal TRS Phones Mode
OFF, ON, Auto. Default: OFF. In Balanced Phones mode output PH 3/4 carries the left channel,
output PH 1/2 the right channel. When Auto is selected, the balanced phones mode is automati-
cally activated as soon as both Phones outputs detect a connector being plugged in. These set-
tings are not valid for the Pentaconn jack, which automatically activates Balanced mode.
Toggle Ph/Line
OFF, 1/2, 3/4, 1/2+3/4, All Plugged, Line/Digital. Default: OFF. Activates the ability to toggle mute
between Phones Out, rear Line Out and digital outputs. Pushing the VOLUME knob for half a
second will then switch between loudspeakers connected to the rear and phones plugged into the
front. All Plugged only incorporates the phones output where a plug is detected. Line/Digital
switches between analog Line Out and digital outputs, with Mute v. Ph active also between
Phones and digital outputs.
Mute v. Ph 1/2
ON, OFF. Default: ON, but grayed out. As soon as a plug is detected in PH 1/2 the rear outputs
1/2 are muted. Note: This function requires Dual Phones to be ON to become accessible. With
Mute v. Ph 1/2 ON the channels Phones 1/2 and Line Out 1/2 have separated settings. Although
both outputs alternately play back the same signal, all settings (Settings, EQ, BT) can be different,
and are separately stored in the background.
Mute v. Ph 3/4
ON, OFF. Default: ON. If set to ON a plug detected in PH 3/4 mutes the rear outputs 1/2.

8.4.3 Clock Settings

Clock Source
Choices are Auto, INT (Internal, Master), AES, SPDIF. Not available in DAC mode.
Sample Rate
This setting can only be changed
when not connected to USB. Oth-
erwise it only serves as info
panel. Choices are 44.1, 48, 88.2,
96, 176.4, 192, 352.8, 384, 705.6
and 768 kHz.