Volume
Mirrors the direct volume control via Volume knob or encoder 1. The output level can be set be-
tween -96 dB and +6 dB, mostly in steps of 0.5 dB.
Lock Volume
Deactivates volume control via the big VOLUME knob.
Dim
Reduces the volume of the current output by 20 dB. Adjusting Volume to a higher value deac-
tivates Dim immediately, lowering Volume will set the Dim value as new Volume value.
Link
Links (or gangs) any of the output volume settings. This feature is similar but not identical to Dual
Volume on the device.
Ref. Auto
ON, Off. Default: ON.
Ref Level
Sets the reference level for the analog outputs 1/2. Choices are +1 dBu, +7 dBu, +13 dBu, +19
dBu, +24 dBu, referenced to digital full scale level (0 dBFS).
Balance
Mirrors the balance control in the VOL screen. Adjustable from L 100 (left) through <C> (center)
to R100 (right).
Mute
Mutes the output.

8.2.2 Parametric EQ

EQ Enable
ON, OFF. Default: OFF.
Preset
Load or store up to 22 different EQ Presets. The first choice, Man-
ual, holds the current, unsaved EQ settings. The second choice,
Temp, holds the settings of a loaded and then modified Preset. This
scheme lets the user easily change and compare three different EQ
settings: the manual one, the stored preset and the modified preset,
without losing changes while listening to a different set of EQ set-
tings.
Preset 21, Clear, corresponds to the factory default with all bands
at 0 dB. It is not available to store a preset, but is used for resetting
one by overwriting. A preset reset in this way, resulting in an 'empty'
preset, is marked with (lin).
The ADI-2/4 Pro SE has Rumble as Preset 22, a rumble filter for
turntable usage.
The EQ Presets are independent from and not stored with Setups
on the device. Using the app Setup files include all 20 PEQ Presets.
On load the current EQ setting is written into the memory slot Man-
ual.
Store
Opens a dialog to store the current PEQ settings as file or into the
device.