Bosch MIC-9502 User Manual page 89

Table of Contents

Advertisement

MIC IP fusion 9000i
Status
Code
20
23
* Note: The MIC IP fusion 9000i camera requires a Bosch 95 W midspan (NPD-9501A) or a
customer-tested/verified alternative.
Caution!
If you choose not to use a switch or midspan with the appropriate Power Sourcing Equipment
!
(PSE) chip, then the MIC camera will not recognize the PoE as compliant, and the camera
firmware may disable some or all functionality.
Bosch Security Systems
Description
Camera is configured to use the
"Hard Pan Limits" (HPL) feature,
and it has been powered-up with
pan position in the forbidden zone.
An internal error has occurred.
(The optical video screen becomes
blue for 1 or 2 seconds during the
camera's recovery procedure.)
User Manual
Recommended action
(to be completed by a qualified Service
Technician)
Temporarily remove one of the hard pan
limits (as described in PTZ Settings, page 39),
pan the camera out of the forbidden zone,
and then restore the hard pan limit.
Reboot the camera by powering the camera
off and then on, or by clicking the button
Reboot in the camera's web browser
(Configuration > Camera > Installer Menu
>Reboot device).
Note: If pan movement is blocked only in one
direction, but possible in the other direction
(as when the camera is near the HPL), then
no status code appears.
If this problem begins to occur on a regular
basis:
1. Verify that the power source to the camera
is not experiencing brown-out conditions.
2. Verify that the camera's earth ground
connection is attached per earlier
instructions.
If these actions do not resolve this problem,
contact the nearest Bosch Security Systems
Service Center.
2017.11 | 0.20 | F.01U.349.011