5-1. Selecting A Location
18 in.
(460 mm)
5-2. Installing Welding Gun
Exposed O-rings
Incorrect
will cause shielding
Gun Not Seated
SECTION 5 − INSTALLATION
.
Be sure that gun end is tight
against drive assembly.
1
3
Gun Fully Seated
gas leakage.
.
A complete Parts List is available at www.HobartWelders.com
2
18 in.
(460 mm)
4
3
2
Correct
1
Plug From Unit
2
Grounded Receptacle
Locate unit near correct input power
supply.
!
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
1
!
Do not move or operate unit
where it could tip.
258 641-A
1
Drive Assembly
2
Gun Securing Thumbscrew
3
Gun End
Loosen thumbscrew. Insert end of
gun through opening in front
panel until it bottoms against
Tighten
drive
assembly.
thumbscrew.
Welding gun must be inserted
completely to prevent leakage of
shielding gas.
4
Gun Trigger Leads
Insert leads, one at a time, through
gun opening on front panel.
Connect female friction terminals to
matching male terminals in unit.
Polarity is not important.
Close door.
258 315-A