www.ti.com
– Clear radio button
Dropdown selection box - selects the DMD block to clear (load "zeros"):
– The DLP9000X DMD and DLP9000XUV DMD have 16 selectable blocks
– The DLP6500 DMD has 15 selectable blocks
– Reset Single: radio button
Dropdown selection box - selects the DMD block to perform a single block reset on:
– The DLP9000X DMD and DLP9000XUV have 16 selectable blocks
– The DLP6500 DMD has 15 selectable blocks
– Reset Dual: radio button
Dropdown selection box - selects the DMD block group to perform a dual block reset on:
– The DLP9000X DMD and DLP9000XUV have the following selectable dual block groups - (1,2),
(3,4), (5,6), (7,8), (9,10), (11,12), (13,14), and (15,16).
– The DLP6500 DMD has the following selectable dual block groups - (1,2), (3,4), (5,6), (7,8), (9,10),
(11,12), (13,14), and (15).
– Reset Quad: radio button
Dropdown selection box - selects the DMD block group to perform a quad block reset on:
– The DLP9000X DMD and DLP9000XUV have the following selectable quad block groups - (1-4),
(5-8), (9-12), and (13-16)
– The DLP6500 DMD has the following selectable quad block groups - (1-4), (5-8), (9-12), and
(13-15)
– Reset Global radio button - sends a reset to all blocks on the DMD at the same time.
– Mirror Float radio button - sends a specialized reset waveform to the DMD mirrors to release the mirrors
and leave them nominally flat.
Mirror Float is NOT a substitute for a DMD Park (PWR_FLOAT) when preparing to shut down
the system.
Once the desired parameters are set press the Set button to send the operation to the Apps FPGA for
execution.