Lincoln Electric BURNY KALIBURN Spirit II 275 User Manual page 86

High current density plasma cutting system with manual gas console (mgc)
Table of Contents

Advertisement

Section 5: Torch Consumables and Cutting Charts
Aluminum - 150 Amps - Air Plasma / Nitrogen Shield
Shield Cap
BK277117
Outer Cap
BK284150
Imperial*
Material
Preflow
Thickness
(in)
(psi)
1/4
3/8
1/2
20
5/8
3/4
Metric*
Material
Preflow
Thickness
(mm)
(psi)
6
10
12
20
16
20
Marking* – For All Material Thicknesses
Type of Gas
Preflow
(Plasma) (Shield)
(psi)
Nitrogen Nitrogen
N/A
Argon**
Air**
N/A
* Use an arc transfer height (ignition height) of .250" (6.4 mm) for cutting and .100" (2.5 mm) for marking.
** Only available on systems with the Automatic Gas Console.
(Revised 04/26/2013)
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Copper Electrode
Nozzle
BK277293
Retaining Cap
BK277152
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
71
50
69
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
71
50
69
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
25
25
N/A
50
25
N/A
5-36
Electrode
BK277292
Swirl Ring
BK277139
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(ipm)
(in)
145
145
.130
155
115
.185
165
90
.230
65
170
.250
45
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(mm/m)
(mm)
143
3770
3.1
156
2825
4.8
162
2430
5.5
170
1630
6.4
170
990
Arc
Travel
Voltage
Speed
(volts)
(ipm) (mm/min)
(in)
135
250
6350
.100
69
100
2540
.100
Spirit II User's Manual
Torch Head
BK279100
Pierce
Pierce
Kerf
Height
Time
Width
(in)
(msec)
(in)
.250
400
.125
.275
500
.300
600
.130
.325
800
.135
.350
1200
.140
Pierce
Pierce
Kerf
Height
Time
Width
(mm)
(msec)
(mm)
6.3
400
3.2
7.0
600
7.4
3.3
8.3
3.4
1200
9.0
3.6
Marking
Initial
Pierce
Height
Height
Time
(mm)
(in) (mm) (msec)
2.5
.100
2.5
0
2.5
.100
2.5
0

Advertisement

Table of Contents
loading

Table of Contents