Lincoln Electric BURNY KALIBURN Spirit II 275 User Manual page 65

High current density plasma cutting system with manual gas console (mgc)
Table of Contents

Advertisement

Spirit II User's Manual
Mild Steel - 70 Amps - Oxygen Plasma / Air Shield
Shield Cap
BK277150
Outer Cap
BK284150
Imperial*
Material
Preflow
Thickness
(in)
(psi)
1/8
3/16
25
1/4
3/8
Metric*
Material
Preflow
Thickness
(mm)
(psi)
3
5
25
6
Marking* – For All Material Thicknesses
Type of Gas
Preflow
(Plasma) (Shield)
(psi)
Nitrogen Nitrogen
N/A
Argon**
Air**
N/A
* Use an arc transfer height (ignition height) of .150" (3.8 mm) for cutting and .100" (2.5 mm) for marking.
** Only available on systems with the Automatic Gas Console.
(Revised 04/26/2013)
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Copper Electrode
Nozzle
BK277125
Retaining Cap
BK277153
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
35
76
74
40
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
35
76
74
40
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
25
25
N/A
50
25
N/A
5-15
Section 5: Torch Consumables and Cutting Charts
Electrode
BK277131
Swirl Ring
BK277142
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(ipm)
(in)
110
190
.100
113
130
116
120
.110
122
75
.140
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(mm/m)
(mm)
109
4995
2.5
113
3265
115
3105
2.7
Arc
Travel
Voltage
Speed
(volts)
(ipm) (mm/min)
(in)
135
250
6350
.096
62
100
2540
.100
Torch Head
BK279100
Pierce
Pierce
Kerf
Height
Time
Width
(in)
(msec)
(in)
.150
100
.080
.200
200
.225
300
.085
.250
400
Pierce
Pierce
Kerf
Height
Time
Width
(mm)
(msec)
(mm)
3.6
100
2.0
5.1
300
5.5
2.2
Marking
Initial
Pierce
Height
Height
Time
(mm)
(in) (mm) (msec)
2.4
.100
2.5
0
2.5
.100
2.5
0

Advertisement

Table of Contents
loading

Table of Contents