Lincoln Electric BURNY KALIBURN Spirit II 275 User Manual page 63

High current density plasma cutting system with manual gas console (mgc)
Table of Contents

Advertisement

Spirit II User's Manual
Mild Steel - 30 Amps - Oxygen Plasma / Oxygen Shield
Shield Cap
BK277145
Outer Cap
BK284150
Imperial*
Material
Preflow
Thickness
(ga)
(in)
(psi)
20
.036
18
.048
16
.060
14
.075
35
12
.105
11
.120
10
.135
Metric*
Material
Preflow
Thickness
(mm)
(psi)
1
1.5
2
35
2.5
3
Marking* – For All Material Thicknesses
Type of Gas
Preflow
(Plasma) (Shield)
(psi)
Nitrogen Nitrogen
N/A
Argon**
Air**
N/A
* Use an arc transfer height (ignition height) of .100" (2.5 mm) for cutting and marking.
** Only available on systems with the Automatic Gas Console.
(Revised 04/26/2013)
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Copper Electrode
Nozzle
BK277120
Retaining Cap
BK277153
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
77
6
75
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
77
6
75
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
25
25
N/A
50
25
N/A
5-13
Section 5: Torch Consumables and Cutting Charts
Electrode
BK277130
Swirl Ring
BK277140
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(ipm)
(in)
120
105
.080
121
97
.090
125
78
126
65
.105
127
55
129
50
.120
131
40
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(mm/m)
(mm)
120
2615
2.0
124
2020
2.6
1615
126
2.7
1455
128
1285
2.9
Arc
Travel
Voltage
Speed
(volts)
(ipm) (mm/min)
(in)
145
250
6350
.177
66
100
2540
.100
Torch Head
BK279100
Pierce
Pierce
Kerf
Height
Time
Width
(in)
(msec)
(in)
100
.062
.110
.065
200
.070
.125
300
Pierce
Pierce
Kerf
Height
Time
Width
(mm)
(msec)
(mm)
100
1.6
2.8
1.7
200
1.8
3.1
300
Marking
Initial
Pierce
Height
Height
Time
(mm)
(in) (mm) (msec)
4.5
.100
2.5
0
2.5
.100
2.5
0