Section 5: Torch Consumables and Cutting Charts
Mild Steel - 100 Amps - Oxygen Plasma / Air Shield
Shield Cap
BK277286
Outer Cap
BK284150
Imperial*
Material
Preflow
Thickness
(in)
(psi)
1/4
3/8
1/2
25
5/8
3/4
Metric*
Material
Preflow
Thickness
(mm)
(psi)
6
10
12
25
16
20
Marking* – For All Material Thicknesses
Type of Gas
Preflow
(Plasma) (Shield)
(psi)
Nitrogen Nitrogen
N/A
Argon**
Air**
N/A
* Use an arc transfer height (ignition height) of .200" (5.1 mm) for cutting and .100" (2.5 mm) for marking.
** Only available on systems with the Automatic Gas Console.
(Revised 04/26/2013)
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Copper Electrode
Nozzle
BK277284
Retaining Cap
BK277151
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
83
26
81
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
83
26
81
Plasma
Shield
Postflow
(psi)
(psi)
(psi)
25
25
N/A
50
25
N/A
5-16
Electrode
BK277282
Swirl Ring
BK277283
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(ipm)
(in)
125
150
.090
100
.130
130
65
.155
143
47
.185
145
35
Arc
Travel
Cutting
Voltage
Speed
Height
(volts)
(mm/m)
(mm)
124
3950
2.1
2405
3.3
130
1850
3.7
143
1180
4.7
145
800
Arc
Travel
Voltage
Speed
(volts)
(ipm) (mm/min)
(in)
130
250
6350
.100
60
100
2540
.100
Spirit II User's Manual
Torch Head
BK279100
Pierce
Pierce
Kerf
Height
Time
Width
(in)
(msec)
(in)
.200
300
.250
400
.090
.300
500
.325
800
.095
.350
1000
Pierce
Pierce
Kerf
Height
Time
Width
(mm)
(msec)
(mm)
4.9
300
6.5
2.3
500
7.3
8.3
1000
2.4
9.0
Marking
Initial
Pierce
Height
Height
Time
(mm)
(in) (mm) (msec)
2.5
.100
2.5
0
2.5
.100
2.5
0