Technical Description Of The Burner; Technical Data - Riello RLS 300/EV FGR Installation, Use And Maintenance Instructions

Dual fuel light oil/ gas burners
Hide thumbs Also See for RLS 300/EV FGR:
Table of Contents

Advertisement

3

Technical description of the burner

3.1

Technical data

Model
Output
(1)
Delivery
(1)
Fuel
Gas maximum delivery
Gas pressure at maximum delivery
Operation
Nozzle
Standard applications
Ambient temperature
Combustion air temperature
Pump
delivery (at 300 PSI)
pressure range
fuel temperature
Noise levels
(3)
Model
Output
(1)
Delivery
(1)
Fuel
Gas maximum delivery
Gas pressure at maximum delivery
Operation
Nozzle
Standard applications
Ambient temperature
Combustion air temperature
Pump
delivery (at 300 PSI)
pressure range
fuel temperature
Noise levels
Sound pressure
(3)
Sound power
Firing Rate for C-ETL Canadian Listing
(*)
Reference conditions: ambient temperature 68 °F (20°C) - Barometric pressure 394" WC - Altitude 329 ft.
(1)
Pressure at test point 20)(Fig. 3 at page 11) with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)
The sound power is measured with the "Free Field" method, as per EN 15036, and according to an "Accuracy: Category 3" measuring
accuracy, as set out in EN ISO 3746
Equivalent Btu values based on 1 USGPH = 140,000 Btu/hr.
(4)
20102963
Technical description of the burner
RLS 300/EV FGR
High
kW
1387 – 4220 (3834*)
MBtu/hr
4732 – 14390 (13082*)
(4)
33.6 – 102.7 (93.4*)
GPH
Low
kW
MBtu/hr
(4)
GPH
SCFH
"WC
(2)
number
°F
°F max
GPH
PSI
° F max
dB(A)
High
kW
MBtu/hr
(4)
GPH
Low
kW
MBtu/hr
(4)
GPH
SCFH
"WC
(2)
number
°F
°F max
GPH
PSI
° F max
dB(A)
.
6
RLS 400/EV FGR
1998 – 4995 (4541*)
6817 – 17042 (15494*)
47.8 – 121.7 (110.6*)
666
2272
16.0
# 2 Fuel oil - Natural gas
14,390
9.0
Low-high or modulating
Boilers: water, steam, thermal oil
32 - 104 (0 - 40 °C)
140 (60 °C)
218
102 - 580
102 - 580
302 (150 °C)
302 (150 °C)
82
RLS 650/EV FGR
3330 – 7270 (6543*)
11362 – 24807 (22325*)
81.1 – 177.1 (159.4*)
1587
5415
38.7
# 2 Fuel oil - Natural gas
24,807
13.1
Low-high or modulating
Boilers: water, steam, thermal oil
32 - 104 (0 - 40 °C)
140 (60 °C)
102 - 435
302 (150 °C)
80
91
GB
RLS 500/EV FGR
2775 – 5740 (5217*)
9468 – 19692 (17800*)
67.6 – 140.6 (127.1*)
888
1243
3030
4241
21.8
30.4
17,042
19,692
13.0
15.0
1
218
290
102 - 580
302 (150 °C)
85
86
RLS 800/EV FGR
3885 – 8990 (8172*)
13256 – 30670 (27882*)
94.5 – 219 (199.1*)
1942
6626
47.1
30,299
19.9
1
403
89.6
100.6
Tab. A