Electrode And Ignition Pilot Adjustment - Riello RLS 300/EV FGR Installation, Use And Maintenance Instructions

Dual fuel light oil/ gas burners
Hide thumbs Also See for RLS 300/EV FGR:
Table of Contents

Advertisement

RLS 650 - 800/EV FGR model (Fig. 14)
 Disconnect the electrical wiring related to oil pump/servomo-
tor, air servomotor and gas pressure switch;
 disconnect the leverages related to air damper and head
movement;
 unscrew the 4 x fixing screws 1);
 release the cable of the electrode 2);
 disconnect
the
oil
connectors 3).
4.7

Electrode and ignition pilot adjustment

Place the electrode and the ignition pilot observing the dimensions
in Fig. 15 and Fig. 16.
RLS 300 - 400 - 500/EV FGR model (Fig. 15)
D11260
pipes
by
unscrewing
the
2
2
27/ 32"
5/ 8"
Installation
While unscrewing, some fuel may leak out.
WARNING
 Release the ignition pilot retainer;
 remove the screw/gas pressure test point 6) of the combus-
tion head;
 unscrew the under part of the elbow until it comes free of its
two
slot;
 extract the internal part 5) of the combustion head.
1
4
3
5
RLS 650 - 800/EV FGR model (Fig. 16)
D11256
Fig. 15
23
GB
7
6
20110686
8
5/ 8"
Fig. 14
Fig. 16
20102963

Advertisement

Table of Contents
loading

Table of Contents