System Specifications: Cme1402 - Scotsman CME1202 User Manual

Scotsman cme1202 ice machine: user guide
Hide thumbs Also See for CME1202:
Table of Contents

Advertisement

CME1202R & CME1402R

SYSTEM SPECIFICATIONS: CME1402

The following numbers are a guideline to field operation. There will be some variation from unit to unit.
The numbers heading the columns are: Condenser air temp./Cabinet air temp./Water temp.
Typical Cycle Time
Standard Harvest Time*
Typical Freeze Cycle
Suction Pressure, End of
Cycle
Typical Freeze Cycle
Discharge Pressure,
End of Cycle
Typical Harvest Cycle
Suction Pressure, Peak
Typical Air Cooled
Harvest Cycle Discharge
Pressure, Min
* See page 13 for harvest time optimization instructions.
Typical Harvest Ice Weight
13.5 to 14.5 lb.
Refrigerant Charge:
336 ounces of R-404A when connected to a MAC 7G condenser
448 ounces of R-404A when connected to a RCE1401 condenser
448 ounces of R-404A when connected to a ERC401 condenser.
Typical Compressor Amp Draw
Single phase
5 minutes into freeze: 15 - 16 Harvest: 22 - 23
Three phase
5 minutes into freeze: 9 - 10
High Pressure Cut Out
High pressure safety, Manual reset, cut out at 450 PSIG
Ice Level Control
Maximum Range = 8 feet
Partial Fill Setting = 21" - 22" from the base of the ice machine
Timer
1 revolution takes 10 minutes (changed from 8 in June 1996)
Cube Size Control
Cut In adjustable between 0
0/70/55
15 - 17 minutes
1
3
minutes
2
35 PSIG
265 PSIG
80 PSIG
155 PSIG
Harvest: 13 - 14
o
0
F. and +25
F.
June 1996
Page 22
90/90/70
16 - 17 minutes
1
3
minutes
2
31-35 PSIG
270 PSIG
90-95 PSIG
180- 200 PSIG
110/90/80
18 - 19 minutes
1
3
minutes
2
36 PSIG
310 PSIG
110 PSIG
235 PSIG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cme1202rCme1402Cme1402r

Table of Contents