For The Installer: Coupling Instructions - Scotsman CME1202 User Manual

Scotsman cme1202 ice machine: user guide
Hide thumbs Also See for CME1202:
Table of Contents

Advertisement

CME1202R & CME1402R

FOR THE INSTALLER: Coupling Instructions

CAUTION
The couplings on the sets of precharged lines are
self sealing when installed properly. Carefully
follow the instructions:
Initial Connections:
1. Remove the protector caps and plugs. Wipe the
seats and threaded surfaces with a clean cloth to
be certain that no foreign matter remains on them.
2. Lubricate the inside of the couplings, especially
the O-Rings with refrigerant oil.
The 1/2 inch discharge line (schrader valve
end) goes to the remote condenser fitting
marked "discharge line".
The 3/8 inch liquid line (schrader valve end)
goes to the remote condenser fitting marked
"liquid line".
The 1/2 inch discharge line goes to the ice
maker fitting marked "discharge line".
The 3/8 inch liquid line goes to the ice maker
fitting marked "liquid line."
DISCHARGE LINE
INSULATION
SCHRADER
VALVES
LIQUID LINE
June 1996
Page 8
Final Connections:
3. Begin tightening the couplings together by
hand, then using two wrenches (it is important that
ONLY the nut on the precharged lines be turned,
the other parts of the couplings must NOT be
allowed to turn or the process will tear out the
diaphragms and they will be loose in the
refrigeration system) tighten the coupling until it
bottoms out or a definite increase in resistance is
felt.
TIGHTENING THE QUICK CONNECTS
4. Using a marker or pen, mark a line lengthwise
from the coupling union nut to the bulkhead. Then
tighten the coupling and additional 1/4 turn. As the
nut turns, the line will show when 1/4 turn is made.
5. After all connections are made, and after the
king valve has been opened, check the couplings
for leaks.

Advertisement