CME1202R & CME1402R
REMOVAL AND REPLACEMENT
Thermostatic Expansion Valve
1. Before replacing this valve, be certain that the
valve is the cause of the problem, and cannot be
adjusted.
2. Remove the front panel.
3. Discharge and recover the refrigerant.
4. Locate the TXV bulb (on the suction line),
remove the clamps and bulb from the tube.
5. With the refrigeration system open, unsweat the
TXV from the tubing.
6. Place the new TXV in position.
7. Wrap the new TXV body with heat sink material.
Do not get any moisture in the valve.
8. Carefully braze the valve to the tubing. Examine
the joints, if they look good proceed to the next
step, if not, re-do them.
9. Install a new dryer, and braze it in place also.
10. Reattach the TXV bulb to the suction line in the
same place as the old one.
11. Evacuate the system to 300 microns.
12. Weigh or measure the nameplate charge into
the receiver.
13. If the machine has been off on the breaker
there may be refrigerant trapped in the oil of the
compressor, so do not restart until the compressor
has been warmed by the crankcase heater for 4
hours. If the compressor was warm throughout the
replacement process, the ice machine may be
restarted without waiting to re-warm the
compressor.
Hot Gas or Liquid Line Valve.
1. Before replacing this valve, be certain that the
valve is the cause of the problem.
2. Remove the front panel.
3. Discharge and recover the refrigerant.
4. Unplug the coil of the valve.
5. With the refrigeration system open, unsweat the
valve from the tubing.
6. Place the new valve in position.
7. Wrap the new valve body with heat sink
material. Do not get any moisture in the valve.
8. Carefully braze the valve to the tubing. Examine
the joints, if they look good proceed to the next
step, if not, re-do them.
9. Install a new dryer, and braze it in place also.
10. Plug the power cord back onto the coil.
11. Evacuate the system to 300 microns.
12. Weigh or measure the nameplate charge into
the receiver.
13. If the machine has been off on the breaker
there may be refrigerant trapped in the oil of the
compressor, so do not restart until the compressor
has been warmed by the crankcase heater for 4
hours. If the compressor was warm throughout the
replacement process, the ice machine may be
restarted without waiting to re-warm the
compressor.