Removal And Replacement - Scotsman CME1202 User Manual

Scotsman cme1202 ice machine: user guide
Hide thumbs Also See for CME1202:
Table of Contents

Advertisement

CME1202R & CME1402R

REMOVAL AND REPLACEMENT

Water Distributor Tubes And Manifold Tubes
To remove the water distributor tube and manifold
tube:
1. Remove the front panel.
2. Slide the water distributor tube to the front about
1/8-inch along the top of the evaporator plate, until
the water distributor tube can be unsnapped from
the flexible notch and lifted upward.
3. Unsnap and disconnect water distributor tubes
from the water manifold section. To replace the
water distributor tubes and manifold tubes, reverse
the removal procedure. BE SURE the notches in
the water manifold tubes properly engage the
alignment keys in the tee. BE SURE the water
distributor tube is securely fastened at the notch at
both sides of the evaporator plate. Check identical
attachment for the left water distributor tube and
notch; also, that the distributor/manifold
connections at the top center of each evaporator
plate is snug against the top of the plate.
Electrical Shock Hazard.
Electrical shock can
cause personal injury.
Disconnect power
before beginning to
service components.
WATER DISTRIBUTOR
Cube Size Control
To remove the cube size control:
1. Remove front panel.
2. Remove cover from control box.
3. Trace capillary tube, from the cube size control
to the refrigerant suction line.
REPLACEMENT OF THE CUBE SIZE CONTROL
4. Remove the coiled capillary tube bulb from the
tube well on the suction line.
5. Remove electrical leads from the cube size
control.
6. Remove screws and pull the capillary tube
through the notch in the back of the control box.
Remove the cube size control. To replace the cube
size control, reverse the removal procedure.
June 1996
Page 28
NOTCH IN BACK OF
CONTROL BOX
CUBE SIZE
CONTROL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cme1202rCme1402Cme1402r

Table of Contents