Governor System
FIELD INSTALLED UPDATED DESIGN Electronic Governor Troubleshooting Flow Chart Continued
Locate Speed Control input wire. This connection is a single wire red with yellow tracer.
12 Volt
See illustration on page 97.
Power
Test
Unplug and connect a jumper wire to red wire with a yellow tracer on engine wire harness.
See illustration on page 97.
Start engine in normal manner as described in Owner's Manual. (Engine will initially operate at speed it was
last run or shut down, then will go to idle). See illustration on page 97.
Attach open end of jumper wire to positive (+) battery terminal. See illustration on page 97.
Engine speed increases
(if it was at low speed).
Fail
Engine speed does not change.
Review GCU blink codes with chart on page 99 to identify if a system condition is present.
Proceed to Ground/Power test for GCU. Refer to page 97.
Inspect wiring harness for broken wire or bad connections. Repair/Replace as required.
Test ground circuit to GCU. Refer to page 97.
Continued on next page
102
Operation Input Voltage:
0-1 Volts at Idle/9+ Volts at High Speed.
Kohler electronic governor system tests OK. Test
Pass
control system of equipment. Refer to Equipment
Manufacturer's diagnostic procedures for control
system.
KohlerEngines.com