Kyocera PE-MF2 Service Manual page 163

Table of Contents

Advertisement

Fax Maintenance
Wait Time
1Dial Tone
Detection
Timeout Length
BT Setting
BT Frequency
BT (Busy Tone)
Detection
BT Level
BT Cadence
RTN Rate
Comm Settings
V34 Modem
V17 Modem
The machine starts dialing after the specified interval without
detection of a dial tone when
Dial tone detection is set to "No detection".
[3.5 Sec (Default)/ 7.0 Sec/ 10.5 Sec
/ 14.0 Sec]
This setting sets the time-out length for the 1st dial tone
detection. The machine waits for a dial tone for the specified
time and disconnects itself from the line when no dial tone
is input.
[10 Sec (Default)/ 15 Sec/ 20 Sec/ 30 Sec]
DFU
[Off/ On]
BT: Busy tone
DFU
[300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550
Hz/ 350-500 Hz/ 350-550 Hz/ 375-475 Hz/
380-520 Hz]
DFU
[-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB]
DFU
[0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/
0.50/ 0.75]
The machine checks the actual data reconstruction errors
and then transmits an RTN depending on the decoding error
rate that is set by this setting (Number of lines containing an
error per page / Total number of lines per page).
[10%/ 15%]
DFU
[Permitted (Default)/ Prohibited]
DFU
[Permitted (Default)/ Prohibited]