Capital's Air Check is a self-contained device designed for indoor BBQ installations, where there is a
requirement for the appliance to have an interlock installed. The Interlock system is designed to only allow the
Gas Valve to open once, the extraction fan is operating. Once the rangehood is operating, gas will flow to the
appliance and the BBQ can be ignited. Ref: AS/NZS 5601.1:2013 Clause 6.10.1.15
Capital's Air check works to prove that there is air flow in the Extraction system. Once the Rangehood is
powered on and extraction commences, the controller detects the air movement via the fitted prove. Once air
movement (Extraction) is proven, the controller will send a signal to the electronic gas valve to open. At this
stage the BBQ your PROGRILL BBQ can be ignited.
Capital's Aircheck ensures that you BBQ safely. Capital's Aircheck will automatically Lock the gas valve and
prevent gas flow, if the rangehood stops working or is working with reduced or unacceptable extraction levels.
The system is also fitted with a Key/twist release emergency stop button on the front panel which, will also cut
the gas supply if pressed.