Table Of Contents; Safety Precautions - Daikin FDMA125AV16 Installation Manual

Table of Contents

Advertisement

Split System Air Conditioner
DAIKIN
INSTALLATION MANUAL <FOR INDOOR UNIT>
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
CONTENTS
1. SAFETY PRECAUTIONS ................................................ 1
2. BEFORE INSTALLATION ................................................ 2
4. PREPARATION BEFORE INSTALLATION ...................... 5
5. INSTALLATION OF INDOOR UNIT ................................. 6
6. REFRIGERANT PIPING WORK ...................................... 7
7. DRAIN PIPING WORK .................................................... 8
8. DUCT WORK ................................................................. 11
9. ELECTRIC WIRING WORK ........................................... 11
10. FIELD SETTING ............................................................ 14
11.
TEST OPERATION ....................................................... 16
12.
by the Kyoto Protocol. Do not vent gases into the atmosphere.
< 1 l
GWP
value: 675*
1 l GWP = global warming potential
<
The refrigerant quantity is indicated on the unit name plate.
*This value is based on F gas regulation (824/2006).

1. SAFETY PRECAUTIONS

Read the precautions in this manual
carefully before operating the unit.
l&I
This appliance is filled with R32.
Please read these "SAFETY CONSIDERATIONS" carefully
before installing air conditioning unit and be sure to install it
correctly. After completing the installation, make sure that
the unit operates properly during the start-up operation.
Please instruct the customer on how to operate the unit and
keep it maintained.
Also, inform customers that they should store this installation
manual along with the operation manual for future reference.
This air conditioner comes under the term "appliances
not accessible to the general public".
This is a class A product. In a domestic environment this
product may cause radio interference in which case the user
may be required to take adequate measures.
• This manual classifies the precautions into WARNINGS and
CAUTIONS.
Be sure to follow all the precautions below: They are all
important for ensuring safety.
&
WARNING
.............. Indicates a potentially
&
CAUTION
............... Indicates a potentially
NEW REFRIGERANT (R32) SERIES
FDMA125AV16, FDMA140AV16
19
hazardous situation which,
if not avoided, could result in
death or serious injury.
hazardous situation which,
if not avoided, may result in
minor or moderate injury.
It may also be used to alert
against unsafe practices.
INSTALL.ATIONMA NUALOFINDOORP�:;·
INSTALLATION MA NUALOFOlJTDOOR 21-41
• After the installation is completed, test the air conditioner
and check if the air conditioner operates properly. Give the
user adequate instructions concerning the use and cleaning
of the indoor unit according to the Operation Manual. Ask the
user to keep this manual in a handy place for future
-&
reference.
WARNING------------
• Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
• The appliance must be stored in a room without continuously
operating ignition sources (for example: open flames,
an operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odor.
• Floor area required for installation of the equipment, refer to
the installation manual of the outdoor unit.
• Comply with national gas regulations.
• Ask your local dealer or qualified personnel to carry out
installation work.
Improper installation may result in water leakage, electric
shocks or a fire.
• Perform installation work in accordance with this installation
manual.
Improper installation may result in water leakage, electric
shocks or a fire.
• Consult your local dealer regarding what to do in case of
refrigerant leakage.
When the air conditioner is installed in a small room, it is
necessary to take proper measures so that the amount of
any leaked refrigerant does not exceed the concentration
limit in the event of a leakage.
Otherwise, this may lead to an accident due to oxygen
deficiency.
• Be sure to use only the specified parts and accessories for
installation work.
Failure to use the specified parts may result in the air
conditioner falling down, water leakage, electric shocks, a
fire, etc.
• Install the air conditioner on a foundation that can withstand
its mass.
Insufficient strength may result in the air conditioner falling
down and causing injury.
In addition, it may lead to vibration of indoor units and cause
unpleasant chattering noise.
• Carry out the specified installation work in consideration of
strong winds, typhoons, or earthquakes.
Improper installation may result in an accident such as air
conditioner falling.
• Make certain that all electrical work is carried out by qualified
personnel according to the applicable legislation (Note 1)
and this installation manual, using a separate circuit.
In addition, even if the wiring is short, make sure to use a
wiring that has sufficient length and never connect additional
wiring to make the length sufficient.
Insufficient capacity of the power supply circuit or improper
electrical construction may lead to electric shocks or a fire.
(Note 1) applicable legislation means "All international,
national and local directives, laws, regulations
and/or codes which are relevant and applicable for
a certain product or domain".