YASKAWA SOLECTRIA XGI 1500-250/250-600 Installation And Operation Manual page 55

Utility scale 1500vdc string inverter
Table of Contents

Advertisement

Installation and Operation Guide SOLECTRIA
Communication
27
3 Fault
28
Network Fault
Software Update
29
Fault
Unauthorized
30
Network Access
Invalid
31
Configuration
Request
32
9.1.3
Information Events
Information events will not cause the inverter to cease producing AC power and are used for reference. There is
no LED for them.
Info
Display Message
Event Code
Power Derating,
1
Temperature
Power Derating,
2
Customer
Command
...
32
DOCR-071074 (Rev 7, 30 MAY 2023)
®
XGI 1500-250 Series Inverters
Communication processor
hardware fault.
A network connection has failed.
Communication processor
software update fault.
An unauthorized attempt to
access the network has occurred.
An external request to adjust
setting beyond the allowable
limits.
Reserved
Table 9-3 Information Event Codes
Description
Inverter output power is reduced
due to the internal operating
temperature of the inverter.
Inverter output power is reduced
in response to user command.
Reserved
Power cycle the inverter. If the inverter
doesn't clear the error, contact
Technical Support.
Check to make sure the Ethernet
connections are firmly seated. Check
the Wi-Fi antennas, ensure they are
vertically mounted.
Power cycle the inverter. If the inverter
doesn't clear the error, contact
Technical Support.
Check to ensure there have not been
any malicious attempts to access the
inverter network.
Check to make sure the value being
entered is acceptable and re-enter.
Troubleshooting
Check to make sure all external fans
are operating, replace fans if
necessary. Make sure the ambient
temperature is within the normal
operating range.
Verify that that a request has been
made to de-rate the inverter. If this
request has not been made, contact
Technical Support.
55 of 72

Advertisement

Table of Contents
loading

Table of Contents