Samsung MWR-WE11N Installation Manual page 20

Hide thumbs Also See for MWR-WE11N:

Advertisement

Wired Remote Controller Installation/Service Mode
AA
Main
Sub
menu
menu
1
2
3
Indoor unit EVA OUT temperature
4
5
Indoor unit option checking (1)
3
6
Indoor unit option checking (2)
1
2
Indoor unit/Ventilator (ERV)
4
option setting 2)*
3
4
7
1
Mini AHU setting/checking
Setting/Checking the discharge
5
2
temperature of the indoor unit
Fresh Duct discharge
3
temperature checking
1
ERV Plus setting/checking
ERV Plus temperature
2
setting/checking
ERV Plus Auto mode
6
3
temperature setting/checking
Setting/checking the compensating temperature A under the
4
Checking the compensating temperature B under the Heating
ERV Plus fan RPM setting/
5
checking
1
View master setting/checking
(F3F4 line Indoor unit master)
2
7
Mode master indoor unit
3
setting/checking
(F1F2 line Indoor unit master) 3)*
4
20
Function
Indoor unit room temperature
Indoor unit EVA IN temperature
Indoor unit EEV step
Use of central control
Use of drain pump
Use of electric heater
Use of hot water coil
Use of external control
Use of RPM compensation
Filter time
Heating temperature
compensation
EEV stop step in heating
Setting/Checking the address
Setting/Checking the product
option
Setting/Checking the
installation option 1
Setting/Checking the
installation option 2
MCU/Port address setting
RPM setting/checking
Humidity setting/checking
Use of discharge
temperature control
Cooling discharge temperature
Heating discharge temperature
Cooling discharge temperature
Heating discharge temperature
Use of cold air prevention
Use of humidification when
Heating thermo off
Use of fan operation in Defrost
Use of humidification when Heating
Cooling
Heating
Set temperature
Set temperature difference
Heating EEV control for ERV Plus
EEV control for ERV Plus
Air supply RPM
Air exhaustion RPM
Indoor unit View master setting/
checking
ERV unit View master setting/
checking
Mode master indoor unit
checking
Mode master indoor unit setting
Data
Factory
Description
bit
setting
1,2,3
-
Room temperature
1,2,3
-
EVA IN temperature
1,2,3
-
EVA OUT temperature
1,2,3
-
EEV step
1
-
0 – No use, 1 - Use
2
-
0 – No use, 1 - Use
3
-
0 – No use, 1 - Use
4
-
0 – No use, 1 - Use
1
-
0 – No use, 1 - Use
2
-
0 – No use, 1 - Use
3
-
0 – 2000 hours, 1 – 1000 hours
4
-
0-2 °C, 1-5 °C
5
-
0 – 1/80 steps, 1 – 80
12
-
MAIN address (00H~4FH)
34
-
MAIN address (00H~4FH)
56
-
Group address (00H~FEH)
1)*
-
Refer to the installation manual
1)*
-
of the connected indoor unit/
ventilator (ERV)
1)*
-
MCU address (00 to 15)
1,2,4
-
Port address (A to F)
3,4
-
0~31 steps
6
-
0 – 30, 1 - 40, 2 - 50
1
-
0 – No use, 1 - Use
3,4
-
8~25 °C (46~77 °F)
5,6
-
18~43 °C (64~109 °F)
1,2
-
13~25 °C (55.4~77 °F)
3,4
-
18~30 °C (64~86 °F)
1
-
0 – No use, 1 - Use
2
-
0 – No use, 1 - Use
3
-
0 – No use, 1 - Use
4
-
0 – No use, 1 - Use
1,2
-
15~30 °C (59~86 °F)
3,4
-
15~30 °C (59~86 °F)
1,2
-
15~30 °C (59~86 °F)
3,4
-
5~15 °C (41~59 °F)
1,2
-
0~10 °C
0 – Non use of humidifier
3
-
(0 °C/32 °F)
1 – Use humidifier(10 °C/50 °F)
1,2
-
10~27 steps
3,4
-
10~27 steps
123456
-
address
123456
-
address
123456
-
address
1
-
0-No use, 1-Use, 2-Release
Unit
°C
°C
°C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 step
-
-
1 °C
1 °C
1 °C
1 °C
-
-
-
-
1 °C
1 °C
1 °C
1 °C
1 °C
-
1 step
1 step
-
-
-
-