Climatiseur de type multiple ( refroidissement et chauffage ) (26 pages)
Summary of Contents for Samsung MWR-TH00
Page 1
MANUAL DE INSTALACIÓN MANUEL D’INSTALLATION MANUALE D’INSTALLZIONE MANUAL DE INSTALAÇÃO INSTALLATIONS-HANDBUCH E°XEIPI¢IO E°KATA™TA™H™ àçëíêìäñàü èé ìëíÄçéÇäÖ Wired Remote Controller MWR-TH00 MWR-TH01 System Air Conditioner Aire acondicionado sistemático Climatiseur numérique multifonctionnel Sistema Aria Condizionata Sistema Ar Condicionado Klimaanlage System ™‡ÛÙËÌ· ∫ÏÈÌ·ÙÈÛÌÔ‡...
Page 2
All manuals and user guides at all-guides.com Safety Precautions This installation manual indicates you to install the wired remote controller which is connected to the indoor unit. For installation of other optional accessories, see an appropriate installation manual. Read carefully this installation manual before WARNING installation and check whether the remote controller is installed correctly after installation.
All manuals and user guides at all-guides.com Contents ..4 IRED REMOTE CONTROLLER AND ACCESSORIES IVIDING THE COM1/COM2 Flowchart for dividing COM1/COM2 ..... . 5 The Diagram of COM1/COM2 .
All manuals and user guides at all-guides.com Wired Remote Controller and Accessories Accessories The following accessories are supplied with the air conditioner. The number of each accessory is indicated in parentheses. Communication Cable-tie (2) Cable clamp (5) M4x16 tapped Indoor Unit Wire joint (1) User’s cable of the wired...
All manuals and user guides at all-guides.com Dividing the COM1/COM2 Flowchart for dividing COM1/COM2 Does the indoor unit support COM2(F3, F4)? (Refer to the indoor unit user's manual.) Install the wired remote controller to Install the wired remote controller to COM2.
All manuals and user guides at all-guides.com Dividing the COM1/COM2 (cont.) The Diagram of COM1/COM2 COM1 Diagram DVM Outdoor unit COM1(F1, F2) Indoor unit MAIN RMC MAIN RMC MAIN RMC Wired remote controller Group control COM2 Diagram DVM PLUS Outdoor unit COM1(F1, F2) Indoor unit COM2(F3, F4)
All manuals and user guides at all-guides.com Installing to COM1(F1, F2) Installing the Communication cable n case of 1-way cassette, connect the terminal BLOCK of the opening part of the indoor unit with the main PCB of indoor unit using the indoor unit power drawing cable as shown in the picture.
All manuals and user guides at all-guides.com Installing to COM1(F1, F2) (cont.) Installation Open the wired remote controller by using 2 grooves on its top. Secure the rear cover of the wired remote controller on the wall with 2 screws. Connect each F1, F2, V1, V2, indoor unit terminal with the wired remote controller terminal F1, F2, V1, V2.
All manuals and user guides at all-guides.com Setting up indoor unit PCB and Wired Remote Controller Option switches Indoor unit PCB If you control the indoor unit with the wired remote controller, adjust K1 of SW4 option switch of the indoor unit PCB to ‘OFF’.
All manuals and user guides at all-guides.com Installing to COM1(F1, F2) (cont.) Examples of installing Wired Remote Controller Individual control : Individual control of 3 indoor units with 3 wired remote controller. Indoor unit PCB DVM Outdoor unit MAIN ADDRESS ADDRESS Indoor unit MAIN RMC...
Page 11
All manuals and user guides at all-guides.com Individual & Group control : Controlling 1 indoor unit of 3 indoor units with ADDRESS ‘0’ of the wired remote controller individually and controlling the other 2 indoor units with ADDRESS ‘1’ of the wired remote controller as a group.
All manuals and user guides at all-guides.com Installing to COM1(F1, F2) (cont.) The errors indicated on the Wired Remote Controller The errors of outdoor unit, indoor unit and optional accessories are indicated on the LCD. If the is indicated, press the button in front of the wired remote controller to display the error code.
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) Installing the Communication cable If the indoor unit is a 1-way cassette, connect the indoor unit PCB to the terminal block within the indoor unit using the power cable of the wired remote controller as shown in the first picture.
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) (cont.) Installation Open the wired remote controller using the 2 grooves on the top. Secure the rear cover of the wired remote controller on the wall with 2 screws. Connect V1, V2 with the wired remote controller terminal V1, V2.
All manuals and user guides at all-guides.com Setting up indoor unit PCB and Wired Remote Controller Option Switches Indoor unit PCB DS01 Adjust the K1 switch(SW4) - option switch of the DS03 indoor unit PCB - to ‘OFF’, which is to be controlled by the wired remote controller.
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) (cont.) The errors indicated on the Wired Remote Controller The error of outdoor unit, indoor unit and optional accessories is indicated on the LCD. If the is indicated, press the button in front of the wired remote controller to display the error code.
All manuals and user guides at all-guides.com Examples of installing Wired Remote Controller Individual contro : Individual control of 1 indoor unit wired remote controller Wired remote controller PCB Indoor unit PCB Outdoor unit COM1 COM1 Indoor unit COM2 COM2 COM2 Wired remote controller Don’t change the default settings of the wired remote controller.
Page 18
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) (cont.) Group control : Controlling more than 2 indoor units with a wired remote controller Wired remote controller PCB Indoor unit PCB Outdoor unit COM1 COM1 COM1 Indoor unit COM2 COM2 Wired remote controller...
Page 19
All manuals and user guides at all-guides.com Group control : The outdoor unit controls 2 different indoor units simultaneously with a wired remote controller. (Except the GHP model) Wired remote controller PCB Indoor unit PCB Outdoor unit Indoor unit Outdoor unit Wired remote controller Indoor unit The wired remote controller controls the indoor units together connected with...
Page 20
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) (cont.) 2-remote controller control : 2-remote controller means 2 wired remote controllers control 1 indoor unit. Set the DS03 switch of the wired remote controller PCB as shown in the picture. Wired remote controller PCB Indoor unit PCB Outdoor unit...
All manuals and user guides at all-guides.com The errors indicated on the GHP Wired Remote Controller The error of outdoor unit, indoor unit and optional accessories is indicated on the LCD. If the is indicated, press the button in front of the wired remote controller to display the error code.
Page 22
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) (cont.) Display Examination Outdoor unit PCB Explanation Trouble frquency Remote (times controller code Sub code Indoor unit fan motor The fan doesn’t operate in set speed or is stopped error - Record of the data is forbidden during power Indoor unit EEPROM...
Page 23
All manuals and user guides at all-guides.com Display Examination Outdoor unit PCB Explanation Trouble frquency Remote (times controller code Sub code Detects higher than 5V for 3 seconds of the Starter error starter voltage during off (15 minutes) Outdoor air Detects the outdoor temperature lower than temperature sensor is °...
Page 24
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) (cont.) Display Examination Outdoor unit PCB Explanation Trouble frquency Remote (times controller code Sub code - Before turning the starter ON, detects engine oil pressure switch OFF for 5 seconds continuously Engine oil pressure - After detecting first 2 times, operate engine switch is disconnected...
Page 25
All manuals and user guides at all-guides.com Display Examination Outdoor unit PCB Explanation Trouble frquency Remote (times controller code Sub code - The engine rotation frequency detects that Engine rotations ordered rotation frequency that is lower than (15 minutes) control error ±...
Page 26
All manuals and user guides at all-guides.com Installing to COM2(F3, F4) (cont.) Display Examination Explanation Trouble Outdoor unit PCB frquency Remote (times controller code Sub code Detects the engine water temperature for Engine water ° operating higher than 105 C for 10 seconds temperature is (15 minutes) °...
Page 27
All manuals and user guides at all-guides.com Display Examination Outdoor unit PCB Explanation Trouble frquency Remote (times controller code Sub code Detects the low pressure switch OFF for Low pressure of 3 seconds continuously when the (15 minutes) refrigerant error compressor is ON Detects low pressure switch OFF for Low pressure switch is...
All manuals and user guides at all-guides.com Additional Function of the Wired Remote Controller When using automatic ADDRESS of DVM PLUS, assign MAIN ADDRESS to the indoor and outdoor unit. The RMC is not assigned to the indoor unit. If you want to control the air conditioner with the centralized controller, you should operate the RMC switch of the indoor unit manually.
Page 29
All manuals and user guides at all-guides.com Wired remote controller PCB Set SW5 of DS02 switch on the wired remote controller PCB to ‘OFF’. SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 DS01 DS02 Set the indoor unit PCB Press the button and button in front of the wired remote control simultaneously for more than...
Page 30
All manuals and user guides at all-guides.com Additional Function of the Wired Remote Controller (cont.) Initial display is displayed if the group has never been set. If the group is set, the LCD receives the current indoor unit ADDRESS(main address) and group ADDRESS (RMC) from the indoor unit and displays them.
All manuals and user guides at all-guides.com Canceling the indoor unit RMC assigned with the Wired Remote Controller Wired remote controller PCB Set SW5 of DS02 switch on the wired remote controller PCB to ‘ON’. SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 DS01 DS02 Press the...
Page 32
All manuals and user guides at all-guides.com Additional Function of the Wired Remote Controller (cont.) Initial display If the group has never been set, the LCD receives the RMC ADDRESS which is set to the indoor unit and displays them. Setting the RMC switch Press the button once to control the indoor unit with...
Page 33
All manuals and user guides at all-guides.com Memo...
Page 34
All manuals and user guides at all-guides.com THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: DIESE KLIMAANLAGE IST FABRIZIERT VON: AYTH H ™Y™KEYH KATA™KEYA™THKE A¶O: ùíéí...