  • Page 1 DVM Hydro Unit_MWR-WW00_IB_EN_03648A(1).indd 26 2013-01-09 오후 2:06:30...
  • Page 2: Air Conditioner

    Wired Remote Control MWR-WW00 Air Conditioner user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register EN ES FR IT AR DB68-03648A(1) DVM Hydro Unit_MWR-WW00_IB_EN_03648A(1).indd 27 2013-01-09 오후 2:06:30...
  • Page 3: Table Of Contents

    Contents PREPARATION PART Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description of each icon .
  • Page 4 ADVANCED PART Setting weekly timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Setting a holiday with weekly timer .
  • Page 5: Preparation Part

    PREPARATION PART Safety precautions This content is intended to protect the user’s safety and prevent property damage . Please read it carefully for correct use of the product . Hazards or unsafe practices that may result in severe personal injury or death . WARNING Hazards or unsafe practices that may result in minor personal injury or property damage .
  • Page 6 FOR OPERATION WARNING If the product generates a strange noise, a burning smell or smoke, stop the operation immediately and contact your nearest service center. f Failure to do so may result in electric shock and fire . When reinstalling the product, please contact a service center. f Failure to do so may result in product malfunction, water leakage, electric shock, or fire .
  • Page 7: Description Of Each Icon

    Description of each icon Display ④ ⑤ ⑥ ⑦ ⑬ ① ⑭ ② ⑩ ③ ⑪ ⑧ ⑨ ⑫ LED indicator (Green: Normal / Red: Need to be checked) On/Off button Temperature control button • Without opening the cover of your wired remote controller, you can turn Hydro Unit on or off or set the desired temperature .
  • Page 8 Classification Indication Function ① Hydro Unit operation (heat/cool/auto/outing/silent) System temperature (water Law temp . / indoor temp . / ② outdoor temp . / discharge water temp . / hot water temp . ) Hydro Unit ③ Temperature (current/desired) ④ Timer (Daily/Weekly/Holiday) ⑤...
  • Page 9: Description Of Each Control

    Description of each control Buttons ⑧ ⑦ ⑨ ① ⑭ ② ⑮ ③ ⑬ ⑫ ④ ⑤ ⑥ ⑩ ⑪ DVM Hydro Unit_MWR-WW00_IB_EN_03648A(1).indd 8 2013-01-09 오후 2:06:20...
  • Page 10 Classification Indication Function ① Turn Hydro Unit on or off (Cool/Heat/Auto) ② Select operation mode ③ Select desired temperature (discharge water/indoor/hot water) ④ Select silent mode ⑤ Select outing mode ⑥ Check current temperature of the system Basic operation button ⑦...
  • Page 11: Hydro Unit Part

    HYDRO UNIT PART Operating basic mode of Hydro Unit Operate basic mode by pressing the [Mode] button . Auto Hydro Unit will automatically adjust the temperature of discharge water with auto mode for indoor heating . Cool You can adjust cooling temperature as you like with cool mode to cool indoor place . f When selecting the heat mode during the cool mode, the cool mode will be canceled .
  • Page 12: Hot Water Mode Of Hydro Unit

    Start Hydro Unit operation by pressing the button. Select the mode you want to operate by pressing the button. Adjust desired temperature by pressing the button. Temperature of You can adjust the desired temperature by 0 . 5 °C within a range of cooling discharge 5°C~25°C .
  • Page 13: Checking Current Temperature

    Checking current temperature You can check current temperature . Check the current temperature by pressing the View button. f Current temperature can be checked in order of (indoor)  (outdoor)  (discharge water)  (hot water)by pressing the View button . f The temperature which a connected indoor unit does not support will not be displayed .
  • Page 14: Outing Mode

    Outing mode Heating can operate at low temperature while you are out with outing mode . Select outing mode by pressing the Outing button. will be displayed and outing mode will operate . Cancel Press any button on the remote controller . • When pressing the Outing button while Hydro Unit stops its operation, indication will appear .
  • Page 15: Setting Weekly Timer

    ADVANCED PART Setting weekly timer You can operate or stop a desired mode on the day and time you reserve . (Only cool/heat mode can be set . ) 1. Press the Timer button. f (Timer) will be displayed and then select 'Weekly' among 'Daily' , 'Weekly' , or 'Holiday' by pressing the [∧]/[∨] button .
  • Page 16 7. After pressing the [>] button, select ’On/Off’ timer. f You can select On or Off by repeatedly pressing the [∧]/[∨] button . f When selecting ‘Off’ , follow 10 or 11 . 8. After pressing the [>] button, select the operation mode. f It is available only for setting Hydro Unit On timer .
  • Page 17: Setting A Holiday With Weekly Timer

    Setting a holiday with weekly timer You can set a holiday with the weekly timer . The set weekly timer will not function when holiday setting is applied . 1. Press the Timer button. f (Timer) is displayed and then select 'Holiday' among 'Daily' , 'Weekly' , or 'Holiday' by pressing the [∧]/[∨] button .
  • Page 18: Canceling A Weekly Timer

    Canceling a weekly timer You can cancel weekly timer function . 1. Press the Timer button. f (Timer) is displayed and (Weekly) will blink . 2. After pressing the [>] button, select the 'Day' you want to cancel. f Select a reserved day by pressing the [∧]/[∨] button . 3.
  • Page 19: Setting Daily Timer

    Setting daily timer Hydro Unit can operate or stop at the time you reserve every day . (Only standard hot water mode can be set . ) 1. Press the Timer button. f (Timer) will be displayed and then select 'Daily' among 'Daily' , 'Weekly' , or 'Holiday' by pressing the [∧]/[∨] button .
  • Page 20 6. After pressing the [>] button, select ’On/Off’ timer. f You can select On or Off by repeatedly pressing the [∧]/[∨] button . f When selecting ‘Off’ , follow step 8 or 9 . • You cannot use timer function for hot water mode(saving/standard/ power) when you select the use of hot water function as no use in the field NOTE specification setting with installation of an wired remote controller or when...
  • Page 21: Setting Additional User Functions

    SETTING ADDITIONAL USER FUNCTIONS How to set the detailed setting (User setting mode) SEG Used Sub-menu Main menu 1 2 3 4 1. If you want to set the filed specification, press the User Set button. f You will enter the User Set mode, and the 'main menu' will be displayed . 2.
  • Page 22 User setting mode Main Sub- Function SEG number Default Range Unit menu menu All lock 0-Unlock, 1-Lock Operation On/Off 0-Unlock, 1-Lock key lock Operation selection 0-Unlock, 1-Lock key lock Partial key lock Temperature setting 0-Unlock, 1-Lock key lock Timer setting key 0-Unlock, 1-Lock lock Current time setting(year)
  • Page 23 How to set the detailed setting (User setting mode) Setting current time (example) 1. Press the User Set button. f 'Main Menu' will be displayed and current time can be set by pressing the [∧]/[∨] buttons and selecting No . 2 . 2.
  • Page 24 7. Select 'day, AM/PM, hour, and minute' in the 'sub-menu' . f You can set 'day, AM/PM, hour, and minute' by pressing the [∧]/[∨] buttons and selecting No . 3 . 8. Select the 'day' you want to set by pressing the [>] button. f You can select 'Day(Sun~Sat)' by pressing the [∧]/[∨] buttons .
  • Page 25: Additional Part

    ADDITIONAL PART Trouble shooting Before reporting the problems of your appliance, please check the trouble shooting table below . PROBLEM SOLUTION • Check if there is a power failure . After checking the status of power supply, operate the product again .
  • Page 26 Memo DVM Hydro Unit_MWR-WW00_IB_EN_03648A(1).indd 25 2013-01-09 오후 2:06:30...