Stage
Wa i t – R e a d y f o r
washing
Washing in progress
Wait – Ready for rin-
sing
Rinsing in progress
Cleaning the filters and delivery heads
Operation to be carried out when the machine is off
and cold.
● Prepare a solution of 4 sachets of detergent
powder Code 69000124 dissolved in a litre of
boiling water in a stainless steel, plastic or glass
recipient (NOT ALUMINIUM OR IRON).
● Remove the filters and immerse them with the filter
holders in the prepared solution, leaving them for
at least 10/20 minutes (all night is better).
● Remove them from the container and rinse them
thoroughly in running water.
Tank cleaning (Fig.10 - 11)
● Remove the cup-stand grille 1 at 2 (Fig.10 - 11)
and clean.
● Check and clean the drainage sump 3 (Fig.10 - 11),
removing any sludge with the help of a spoon.
11.3. Regular-interval maintenance
and repairs
During all maintenance / repair operations, the
components used must be warranted to maintain
all the machine's hygiene and safety requirements.
Using the machine's original spare parts constitute
an effective warranty.
After repair or component replacement operations
involving parts coming into contact with water and/or
food, it is necessary to run the machine washing
procedure as specified under the installation and
first-time start-up section herein.
LED signal
SLOW flashing orange
+ blue
Orange + 1 FLASHING
blue
FAST flashing orange
+ blue
Orange + 2 FLASHING
blue
11.3.1. Renewal of water in the boiler
(Fig.12)
To be carried out only by qualified personnel.
● Turn off the machine and wait for the pressure in
the boiler to diminish (gauge needl on "0").
● Remove the cup-holder grid.
● Insert a rubber hose (1) into the hose-end fitting (2)
● Loosen the hose-end fitting (2).
● Allow the water to flow out completely; then, close
the fitting (2) and remove the rubber hose (1).
● Refill the boiler (paragraph 7.3.).

11.3.2. Softener regeneration

Softener DP2 - DP4
Regenerate the water softener within the time-limi-
ts specified for the softener as follows:
DP2
nr.1 regeneration per month for 500 coffees/day;
nr.2 regenerations per month (once a fortnight) for
1000 coffees/day.
DP4
nr.1 regeneration per month for 1000 coffees/day;
nr.2 regenerations per month (once a fortnight) for
2000 coffees/day.
This table has been drawn up according to a water
hardness of 25 degress calculated on the French
scale.
See the documentation included with the softener
for the instructions for use.
Model S TANK (Fig.13)
Operation to be carried out when the machi-
ne is off and cold and with the plug discon-
nected.
To be effected after the consumption of approx.15
litres of water (average hardness calculated as 35
degress on the French scale) or at least once a
month.
● Prepare a solution in a glass of water adding three
teaspoons of fine salt (the salt must be properly
dissolved).
● Drain the water-tank, see point 10.2.
● Slide the softener 1 (Fig.13) off the rubber tubing
2 and turn it over.
● Pour the solution through the filter and the resin,
letting it flow down freely.
● Wait about 5 minutes, then hold the softener un-
der a tap and rinse it with water. When the water
coming out of the softener is no longer salty, the
resins are regenerated and the softener is ready
for use once again.