8
These merchandisers are manufactured to meet ANSI/National Sanitation
Foundation Standard #7 requirements.
We reserve the right to change or revise specifications and
product design in connection with any feature of our
products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
CUL Listed
UL Sanitation
Specialty Products
DSF
1 of 8
DSF
Technical Data Sheet
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75F and 55% R.H.
Discharge Air (F)
28
Evaporator (F)
20
Note: Not recommended to control temp by regulating
coil temp allow t-stat to cycle and control temp.
Btu/hr/ft* DSF CENTER DISPLAY
Parallel
700
Conventional
805
Btu/hr/ft* DSF INLET
Parallel
400
Conventional
460
*For all refrigeration equipment other than Hussmann,
use conventional Btu values.
DEFROST DATA
Frequency Hrs
OFFTIME
Temp Term °F
Failsafe Minutes
ELECTRIC or GAS
Not Recommended
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
Merchandiser Liquid Line (in.)
Merchandiser Suction Line (in.)
Estimated Charge (lb)***
4ft
5ft
6ft
*Dependent on case length and refrigerant type.
*** This is an average for all refrigerants types. Actual
refrigerant charge may vary by approximately half a
pound.
GLYCOL REQUIREMENTS
GPM
PSI
NA
NA
NA
NA
NA
NA
Rev B
8
54
46
2
3/8*
5/8*
1.2
1.5
1.8