Spec Sheet (Cont'd)
REFRIGERATION DATA:
CASE LENGTHS/
CASE USAGE
WEDGES
3',4',5'
FRESH SEAFOOD
45° IS
FRESH SEAFOOD
45° OS
FRESH SEAFOOD
30° OS
FRESH SEAFOOD
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
2) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
3) THE PRINCIPAL COOLING EFFECT IN FISH CASES IS ACCOMPLISHED WITH A TRADITIONAL ICE BED. THE REFRIGERATION
PRESERVES THE ICE AND MAINTAINS A COLD PROTECTIVE LAYER OVER THE PRODUCT.
4) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
CUT
CUT IN
OUT
USAGE
(ºF)
(ºF)
33
30
FRESH SEAFOOD
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
EVAPORATOR FANS
CASE LENGTH
# OF
BLADE
EVAP
DIA. (IN.)
FANS
3'
1
6.7
4'
1
6.7
5'
2
6.7
45° IS
1
6.7
45° OS
1
6.7
30° OS
1
6.7
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CANOPY
LIGHTS
CASE LENGTH
H.O. LED
AMPS
WATTS
3'
N/A
N/A
4'
N/A
N/A
5'
N/A
N/A
45° IS
N/A
N/A
45° OS
N/A
N/A
30° OS
N/A
N/A
SERVICE SEAFOOD - DEEP SERVICE FISH INLET
HUSSMANN - DSFI REMOTE (CHINO)
CAPACITY ***
(BTU/HR/FT) (TOTAL
TEMPERATURE (ºF)
FOR WEDGES)
RATING CONDITION
EVAPORATOR
NSF 7
AHRI 1200
NSF 7
AHRI 1200
250
250
26
26
500
500
26
26
1200
1200
26
26
1000
1000
26
26
DEFROST
DEFROST
TIME
FREQUENCY
TYPE
(MIN)
(#/DAY)
OFF TIME
46
3
CANOPY LIGHTS
LED
BLADE
AMPS
WATTS
AMPS
PITCH (°)
10
0.6
50
N/A
10
0.6
50
N/A
10
1.2
100
N/A
10
0.6
50
N/A
10
0.6
50
N/A
10
0.6
50
N/A
MAX. H.O. LED
OPTIONAL SHELF
LOAD
AMPS
WATTS
AMPS
WATTS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
VELOCITY
(FT/MIN)
DISCHARGE
AIR ** (°F)
NSF 7
NSF 7
32
500
32
500
32
500
32
500
TERM.
DEFROST
DRIP
TEMP
WATER
(°F) COIL
TIME
(LBS/DAY/FT)
ONLY
48
N/A
1.1
OPTIONAL LED
MAX. LED LOAD
SHELF
(W/ ALL
LIGHTS
OPTIONS)
WATTS AMPS WATTS AMPS WATTS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CASE ENERGY USAGE DATA:
TDA/V (ft /ft)
CASE LENGTH /
WEDGES
(ft
3
wedges)
',4',5',6',8',10',12
22.5° IS
22.5° OS
45° OS
45° IS
90° OS
9
REVISION DATE
EST.
GLYCOL (20°F
REFG.
CASE
INLET, 6° RISE)
LENGTH
CHRG.
404A
S
GPM
PSI
(LBS)
3'
0.5
0.3
0.1
4'
0.7
0.4
0.3
5'
0.9
0.4
0.7
45° IS
0.2
0.2
0.3
45° OS
0.2
0.4
1.7
30° OS
0.2
0.3
1.1
END PANEL WIDTH KEY
# OF
END PNL
TOTAL ADDED
END
WIDTH
LENGTH (IN.)
PNLS
(IN.)
1
1.125
1.125
2
1.125
2.25
ANTI-SWEAT
CONVENIENCE
HEATERS
OUTLETS (OPTIONAL)
#
AMPS
WATTS
OUTLET
VOLTS
AMPS
S
0.1
17
1
115
15
0.2
23
1
115
15
0.2
29
1
115
15
0.1
11
N/A
N/A
N/A
0.2
29
N/A
N/A
N/A
0.2
23
N/A
N/A
N/A
ACTUAL CDEC
MAX ALLOWABLE
2
(KWh/day/ft)
CDEC (KWh/Day/ft)
(KWh/day wedges)
(KWh/day wedges)
0
0.53
0.27
0
0.00
3.18
0
0.00
3.18
0
0.00
3.18
0
0.00
3.18
0
0.00
3.18
02/02/17
HUMIDITY SYSTEM
FANS (OPTIONAL)
(3" AXIAL FAN)
# OF
AMPS WATTS
FANS
1
0.1
8
1
0.1
8
1
0.1
8
1
0.1
8
1
0.1
8
1
0.1
8

Advertisement