Hussmann DSF Installation And Operation Manual page 13

Open fish service case
Table of Contents

Advertisement

Spec Sheet (Cont'd)
SERVICE SEAFOOD
HUSSMANN - DSFN REMOTE (CHINO)
REFRIGERATION DATA:
RATING CONDITION
CASE LENGTHS
CASE USAGE
3',4',5',6',8',10',12'
FRESH SEAFOOD
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
2) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABL
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
3) THE PRINCIPAL COOLING EFFECT IN FISH CASES IS ACCOMPLISHED WITH A TRADITIONAL ICE BED. THE REFRIGERATION
PRESERVES THE ICE AND MAINTAINS A COLD PROTECTIVE LAYER OVER THE PRODUCT.
4) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
CUT
CUT IN
USAGE
OUT
(ºF)
(ºF)
33
30
OFF TIME
FRESH SEAFOOD
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
EVAPORATOR FANS
CASE LENGTH
# OF
BLADE
EVAP
DIA. (IN.)
PITCH (°)
FANS
3'
1
6.7
4'
1
6.7
5'
1
6.7
6'
2
6.7
8'
2
6.7
10'
3
6.7
12'
3
6.7
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
BOOM LIGHTS
H.O. LED
OPTIONAL SHELF
CASE LENGTH
(OPTIONAL)
AMPS
WATTS
3'
0.6
71
4'
1.1
128
5'
1.8
202
6'
1.2
142
8'
2.2
256
405
10'
3.5
12'
3.3
383
CAPACITY ***
TEMPERATURE (ºF)
(BTU/HR/FT)
EVAPORATOR
AHRI
AHRI
NSF 7
NSF 7
1200
1200
250
250
24
24
DEFROST
TIME
FREQUENCY
TYPE
(MIN)
(°F) COIL
(#/DAY)
46
3
OPTIONAL
BOOM LIGHTS
LED
BLADE
AMPS
WATTS
AMPS
WATTS
10
0.6
50
0.5
10
0.6
50
0.9
10
0.6
50
1.5
10
1.2
100
1.0
10
1.2
100
1.9
10
1.9
150
3.0
10
1.9
150
2.8
MAX. H.O. LED
LOAD
AMPS
WATTS
AMPS
WATTS
N/A
N/A
0.6
71
N/A
N/A
1.1
128
N/A
N/A
1.8
202
N/A
N/A
1.2
142
N/A
N/A
2.2
256
N/A
N/A
3.5
405
N/A
N/A
3.3
383
VELOCITY
DISCHARGE
(FT/MIN)
AIR ** (°F)
NSF 7
NSF 7
32
500
TERM.
DEFROST
DRIP
TEMP
WATER
TIME
(LBS/DAY/FT)
ONLY
48
N/A
1.1
OPTIONAL LED
MAX. LED LOAD
SHELF LIGHTS
(W/ ALL OPTIONS)
AMPS
WATTS
AMPS
WATTS
58
N/A
N/A
0.5
58
108
N/A
N/A
0.9
108
170
N/A
N/A
1.5
170
116
N/A
N/A
1.0
116
215
N/A
N/A
1.9
215
339
N/A
N/A
3.0
339
323
N/A
N/A
2.8
323
CASE ENERGY USAGE DATA:
TDA/V (ft
CASE LENGTH /
WEDGES
(ft
3
3',4',5',6',8',10',12'
22.5° IS
22.5° OS
45° OS
45° IS
90° OS
13
CASE
LENGT
HS
3'
4'
5'
6'
8'
10'
12'
END PANEL WIDTH KEY
# OF
END
PNLS
1
2
ANTI-SWEAT
CONVENIENCE
HEATERS
OUTLETS (OPTIONAL)
#
AMPS
WATTS
VOLTS AMPS
OUTLETS
0.1
17
1
115
0.2
23
1
115
0.2
29
1
115
0.3
34
1
115
0.4
46
1
115
0.5
57
1
115
0.6
68
1
115
ACTUAL CDEC
MAX ALLOWABLE
2
/ft)
(KWh/day/ft)
CDEC (KWh/Day/ft)
wedges)
(KWh/day wedges)
(KWh/day wedges)
2.59
1.59
2.11
25.9
18.09
20.27
31.08
19.12
23.69
0
0.00
0.00
0
0.00
0.00
0
0.00
0.00
REVISION DATE
02/02/17
EST.
GLYCOL (20°F
REFG.
INLET, 6° RISE)
CHRG.
404A
GPM
PSI
(LBS)
0.5
0.3
0.1
0.7
0.3
0.3
0.9
0.4
0.6
1.1
0.5
1.0
1.5
0.7
0.5
1.9
0.8
0.9
2.4
1.0
1.3
END
TOTAL ADDED
PNL
LENGTH (IN.)
WIDTH
(IN.)
1.125
1.125
2.25
1.125
HUMIDITY SYSTEM
FANS (OPTIONAL)
(3" AXIAL FAN)
# OF
EVAP
AMPS WATTS
FANS
15
1
0.1
8
15
1
0.1
8
15
1
0.1
8
15
1
0.1
8
15
1
0.1
8
15
1
0.1
8
15
2
0.2
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

DsfiDsfmDsfnDsfn-ep

Table of Contents