Hussmann DSF Installation And Operation Manual page 14

Open fish service case
Table of Contents

Advertisement

Spec Sheet (Cont'd)
SERVICE SEAFOOD
HUSSMANN - DSFN-EP-R (CHINO)
3"
25 3/8" 24"
2 5/8"
25 5/8"
48 3/4"
18 5/8"
7/8"
6 1/8"
27"
35 7/8"
REFRIGERATION DATA:
CASE LENGTHS
CASE USAGE
RATING CONDITION
2',3',4',5',
FRESH SEAFOOD
6',8',10',12'
45°O
FRESH SEAFOOD
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
2) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
3) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
CUT
CUT IN
USAGE
OUT
(ºF)
(ºF)
31
29
BLOWER COIL
OFF TIME
31
30
SPIRAL COIL
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
EVAPORATOR FANS
CASE LENGTH
# OF
BLADE
EVAP
DIA. (IN.)
PITCH (°)
FANS
2'
1
6.7
3'
1
6.7
4'
1
6.7
5'
2
6.7
6'
2
6.7
8'
2
6.7
10'
4
6.7
12'
3
6.7
45°O
2
6.7
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
OPTIONAL
SHELF
CASE LENGTH
AMPS
WATTS
2'
N/A
N/A
3'
N/A
N/A
4'
N/A
N/A
5'
N/A
N/A
6'
N/A
N/A
8'
N/A
N/A
10'
N/A
N/A
12'
N/A
N/A
45°O
N/A
N/A
3"
39 3/4"
33 3/4"
1 7/8"
CAPACITY ***
(BTU/HR/FT) (TOTAL
TEMPERATURE (ºF)
FOR WEDGES)
EVAPORATOR
AHRI
AHRI
NSF 7
NSF 7
1200
1200
320
320
22
22
2000
2000
22
22
DEFROST
TIME
FREQUENCY
(°F) COIL
TYPE
(MIN)
(#/DAY)
46
3
OPTIONAL LED
SHELF LIGHTS
BLADE
AMPS
WATTS
AMPS
WATTS
15
0.6
50
N/A
15
0.6
50
N/A
15
0.6
50
N/A
15
1.2
100
N/A
15
1.2
100
N/A
15
1.2
100
N/A
15
2.5
200
N/A
15
1.9
150
N/A
15
1.2
100
N/A
MAX. H.O. LED
LOAD
AMPS
WATTS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
VELOCITY
(FT/MIN)
DISCHARGE
AIR ** (°F)
NSF 7
NSF 7
32
50~100
32
50~100
TERM.
DEFROST
DRIP
TEMP
WATER
TIME
(LBS/DAY/FT)
ONLY
48
N/A
TBD
48
N/A
ANTI-SWEAT
MAX. LED LOAD
(W/ ALL OPTIONS)
HEATERS
AMPS
WATTS
AMPS
WATTS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
14
CASE
LENGT
45°O
# OF
END
PNLS
HUMIDITY SYSTEM
CONVENIENCE OUTLETS
FANS (OPTIONAL)
(OPTIONAL)
(3" AXIAL FAN)
# OF
#
VOLTS
AMPS
EVAP
AMPS WATTS
OUTLETS
FANS
1
115
15
1
1
115
15
1
1
115
15
1
1
115
15
1
1
115
15
1
1
115
15
1
1
115
15
1
1
115
15
1
1
115
15
1
REVISION DATE
06/21/18
EST.
GLYCOL (20°F
REFG.
INLET, 6° RISE)
CHRG.
HS
404A
GPM
PSI
(LBS)
2'
0.3
0.2
0.0
3'
0.5
0.3
0.0
4'
0.7
0.4
0.3
5'
0.9
0.6
0.5
6'
1.1
0.7
0.9
8'
1.5
0.8
0.5
10'
1.9
1.0
0.8
12'
2.4
1.2
1.2
0.4
3.2
2.8
END PANEL WIDTH KEY
END
PNL
TOTAL ADDED
WIDTH
LENGTH (IN.)
(IN.)
1
1.125
1.125
2
1.125
2.25
0.1
8
0.1
8
0.1
8
0.1
8
0.1
8
0.1
8
0.1
8
0.1
8
0.1
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

DsfiDsfmDsfnDsfn-ep

Table of Contents