Error Messages; Aborted Command; Illegal Request; Already Selected - Roland VS-2480 Supplementary Manual

Digital studio workstation
Hide thumbs Also See for VS-2480:
Table of Contents

Advertisement

Error Messages

Aborted Command!

Illegal Request!

This disk drive cannot be used by the VS-2480/2480CD.

Already Selected

This disk drive you've chosen is already the selected drive.

Arbitration Failed!

Busy Status!

Check Condition!

Drive Status Error!

No Drive Found.

The disk drive could not be accessed. Make sure that the disk
drive is connected correctly.

Blank Disc

The CD in your drive is blank. Insert a CD or CD-R/RW that
contains recorded material.
Can't Communicate!
Drive Time-out!
Message Error!
Phase Mismatch!
Undefined Sense!
Unknown Drive Error!
There is a problem with your disk drive connection. Make
sure the disk drive is connected correctly.
Cannot write in "Track at Once" format on
CD-RW Disc!
You have tried to write the audio data in "Track at Once"
format with a CD-RW disc in the drive.

Can't record CD!

Digital recording from a CD player is not enabled. Please
read "CD Digital Parameter" and "Changing the Routing (EZ
Routing Condition)" (Owner's Manual).

Can't Recover Project!

The drive check Recover procedure could not be executed
because there was not enough free space on the disk. Delete
unneeded projects or use the Project Optimize procedure.

Can't Set Marker!

Track number markers must be at least four seconds apart.

Change to Internal Clock?

No digital signal is being received by the DIGITAL IN
connector. Switch the sample rate reference clock to the VS-
2480/2480CD's internal clock by pressing [ENTER/YES].
After checking to make sure that all digital devices are
properly connected and that the sample rates for all of the
devices match, try this operation again.
COAXIAL In Lock
OPTICAL In Lock
R-BUS1 Lock
R-BUS2 Lock
WORD CLOCK In Lock
The sample rate reference clock is set by the digital signal
received at the DIGITAL IN connector as shown above. You
can now record the digital signal.

COAXIAL In Unlock

OPTICAL In Unlock

R-BUS1 Unlock
R-BUS2 Unlock
WORD CLOCK In Unlock
You cannot yet record the incoming digital audio because it
is not being received by the DIGITAL IN connector as shown
above, or because the project sample rate and the sample rate
of the digital device connected to the DIGITAL IN are
different.
Done!
The operation was a success.

Disk Memory Full!

There is insufficient free space on the disk. Erase unneeded
data or select a different disk drive. The current disk
partition already contains 200 projects, the maximum
number of projects it can hold. Delete unneeded projects or
select a different disk drive.

Drive Busy!

If this message appears when you first begin using a disk
drive with the VS-2480/2480CD, the disk drive is not fast
enough. You may still be able to use this disk with projects
that have a lower sample rate or use a different recording
mode.
If this message appears after you have been using a disk
drive with the VS-2480/2480CD, the data on the disk drive
has become fragmented. This will unacceptably slow down
the reading and writing of data. Try bouncing the current
track to re-record its data onto another track, or optimize
your project. If this message still appears after these
measures have been taken, copy the project data to another
disk drive and initialize the disk drive that experienced the
problem.

Event Memory Full!

The project already contains all of the events it can hold.
Delete unneeded automix data or perform a Project Optimize
operation.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vs-2480cd

Table of Contents